NAME: Carbonyl Fluoride
IMIS: C105
CAS: 353-50-4
Exposure Limits
ACGIH TLV:
2 ppm, 5.4 mg/m3 TWA; 5 ppm, 13 mg/m3 STEL
NIOSH REL: 2 ppm TWA; 5 ppm STEL
Health Factors
Monitoring
PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):
MEDIA:
Midget Fritted Glass Bubbler containing 10 mL 0.1 N NaOH
MAX V:
480 Liters MAX F:
2.0 L/min (TWA)
MAX V:
30 Liters MAX F:
2.0 L/min (STEL)
ANL 1:
Ion Specific Electrode; ISE
REF:
2 (OSHA In-House file)
CLASS:
Not Validated
NOTE:
Submit as a separate sample; analyte hydrolyzes instantly to fluoride in water. Analysis is for total F-. Proposed method + follows OSHA method ID-110.
WIPE:
No
|