skip navigational links Occupational Safety & Health Administration DOL.gov OSHA.gov DOL.gov
www.OSHA.gov
Chemical Sampling Information
Hydrogenated Terphenyls
 Field Definitions
 Analytical Methods
 Health Guidelines
General Description

NAME: Hydrogenated Terphenyls

IMIS: 1415

CAS: 61788-32-7

NIOSH: RTECS WZ6535000; 80299

DESCRIPTION:

Solid.

Exposure Limits

ACGIH TLV: 0.5 ppm, 4.9 mg/m3 TWA

NIOSH REL: 0.5 ppm TWA

Health Factors

HEALTH EFFECTS: Cumulative liver and kidney damage (HE3) Cumulative lung damage (HE10)

Monitoring

PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):



MEDIA: Polytetrafluoroethylene (PTFE) Filter, 0.5 microns - (FH)
ANL SOLVENT: Carbon Disulfide
MAX V: 30 Liters   MAX F: 3.0 L/min
ANL 1: Gas Chromatography; GC/FID
REF: 2 (OSHA In-house file)
CLASS: Not Validated
NOTE: Immediately after sampling, transfer filter and backup pad to a small glass screw cap bottle. A bulk of the material must be submitted for analysis.


Revision Date: 08/24/1992
* All Trademarks are the property of their respective owners.
Back to TopBack to Top www.osha.gov www.dol.gov

Contact Us | Freedom of Information Act | Customer Survey
Privacy and Security Statement | Disclaimers
Occupational Safety & Health Administration
200 Constitution Avenue, NW
Washington, DC 20210