WTC OSHA Asbestos Sampling Data for C4

Permissible Exposure Limit (PEL): 0.1 fiber/cubic centimeter as an 8-hr time weighted average.
Excursion Limit: 1 fiber/cubic centimeter over a 30-minute period.
| DATE |
Location |
# of Samples |
Sample Type |
Fibers /cc |
| 9/13 |
Water & Broad St. |
1 |
Personal |
0.003 |
| 9/15 |
Wall & S. William to Pearl & State Streets |
4 |
Personal |
<0.026-0.051 |
| 9/15 |
Broadway & Wall to S. William & Mill Lane |
4 |
Personal |
<0.026-0.035 |
| 9/16 |
Water & Wall to Beekman & Pearl Streets |
1 |
Personal |
0.006 |
| 9/16 |
Exchange Place & New St. |
1 |
Personal |
0.009 |
| DATE |
Location |
Sample Type |
Fibers/cc |
TEM fibers/cc |
| 9/18 |
New & Beaver |
Area |
<0.005 |
none |
| 9/21 |
Corner of Water & Vietnam Vet. Plaza |
Area |
<0.006 |
|
| 9/21 |
Corner of New & Beaver |
Area |
<0.05 |
|
|