• Standard Number: 1926.500(b)(2) ; 1926.501(b)(1)


OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can consult OSHA's website at http://www.osha.gov.


Letter # 20070417-7634

Re: Fall protection requirements for employees on construction equipment

Question: Employees at times perform various tasks on construction equipment being used at a construction site, such as checking fluid levels. At times this work is done while the employee is on the vehicle at heights over more than 6 feet. Do any OSHA construction standards require fall protection for employees who are on construction equipment, such as excavators, dump trucks, and bulldozers at heights in excess of 6 feet?

Answer: The OSHA standards for fall protection in 29 CFR 1926 Subpart M do not apply in this situation because Subpart M explicitly excludes vehicles. 29 CFR 1926.501(b)(1) states:
Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.
The phrase "walking/working surface" is defined at 29 CFR 1926.500(b)(2) as:
Any surface, whether horizontal or