CADMIUM FUME (as Cd)‡
CAS # | 1306-19-0 |
---|---|
Formula |
CdO |
Synonyms |
cadmium monoxide; cadmium oxide fume |
Physical description | odorless, yellow-brown, finely divided particulate dispersed in air. | ||
---|---|---|---|
Boiling point | 2838°F (sublimes) | Molecular weight | 128.4 |
Freezing point/melting point | 2599°F | Vapor pressure | 0 mmHg (approx) |
Flash point | Vapor density | ||
Specific gravity | 8.65 (metal) | Ionization potential | |
Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
NFPA health rating | NFPA fire rating | ||
NFPA reactivity rating | NFPA special instruction | ||
Vapor hazard ratio (VHR) | |||
Historical exceedance percentage | |||
Target organs |
Analyte code (IMIS no.) | |||
---|---|---|---|
Sampling group | |||
Sampler/Sampling media | |||
Sampling time* | |||
Sampling volume (TWA)* | |||
Sampling flow rate (TWA)* | |||
Sampling volume (STEL/Peak/C)* | |||
Sampling flow rate (STEL/Peak/C)* | |||
Analytical method instruments | |||
Method reference | |||
Notes | See CADMIUM |
||
Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
Wipe Sampler/Sampling media | |
---|---|
Bulk Method |
Device | |||||
---|---|---|---|---|---|
Model/Type | |||||
Sampling information (see manufacturer instructions) |
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
---|---|---|---|---|---|---|---|
PEL-TWA |
5 µg/m³ [2.5 µ/mg³ Action Level] |
REL-TWA | TLV-TWA |
0.01 mg/m³, 0.02 mg/m³ (respirable particulate matter) [1990] |
PEL-TWA |
0.005 mg/m³ |
|
PEL-STEL | REL-STEL | TLV-STEL | PEL-STEL | ||||
PEL-C | REL-C | TLV-C | PEL-C | ||||
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Notes:
See 29 CFR 1910.1027 App A. See 29 CFR 1910.1000 Table Z-2 for any operations or sectors where the exposure limits in 1910.1027 or 1926.1127 are stayed or otherwise not in effect. |
Notes:
CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION (LOQ 0.1 mg/m³). See Appendix A |
Notes:
BEI® |
Notes:
See also California Code of Regulations, Title 8 §1532. Cadmium.(construction), and §5207. Cadmium.(General industry). |
||||
Health factors: See NIH-NLM PubChem. | IDLH | ||||||
Carcinogenic classifications: IARC-1, NIOSH-Ca, NTP-K, OSHA-Ca, TLV-A2 |
Notes:
Ca |
||||||
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3: |
Additional Resources and Literature References
NOAA: CAMEO Chemicals - Cadmium oxide NIOSH: Pocket Guide to Chemical Hazards - Cadmium fume (as Cd) Literature References
|
Last Updated Date : 12/18/2020