CARBON DIOXIDE†
CAS # | 124-38-9 |
---|---|
Formula |
CO₂ |
Synonyms |
carbonic acid gas; dry ice |
Physical description | Colorless, odorless gas. | ||
---|---|---|---|
Boiling point | sublimes | Molecular weight | 44.0 |
Freezing point/melting point | -109°F (sublimes) | Vapor pressure | 56.5 atm |
Flash point | Vapor density | 1.53 | |
Specific gravity | 1.56 at -110.2°F | Ionization potential | 13.77 eV |
Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
NFPA health rating | NFPA fire rating | ||
NFPA reactivity rating | NFPA special instruction | ||
Vapor hazard ratio (VHR) | |||
Historical exceedance percentage | |||
Target organs |
Analyte code (IMIS no.) | 0530 | 0530 | |
---|---|---|---|
Sampling group | |||
Sampler/Sampling media | Dräger X-am 5600 Multi-Gas Detector with DrägerSensor IR CO2 ES NDIR sensor. | Five layer aluminized gas sampling bag [Calibrated Instruments GSB-P/10] | |
Sampling time* | |||
Sampling volume (TWA)* | 2-5 L |
||
Sampling flow rate (TWA)* | 0.01-0.05 L/min |
||
Sampling volume (STEL/Peak/C)* | 2-5 L |
||
Sampling flow rate (STEL/Peak/C)* | 0.3 L/min |
||
Analytical method instruments | GC-TCD | ||
Method reference | OSHA 1027 (fully validated) | OSHA ID-172 (fully validated) | |
Notes | Use detector tubes for screening. If greater than PEL, order gas sampling bags. *Note for sampling with Cali-5-BondTM, 10 liter, five layer aluminized gas sampling bag: This gas sampling bag has an integrated twist on/off valve (V-NPB-2/00) Septum (A-SEPT/.750). The nickel-plated brass connection allows the user to control gas flow into or out of the bag by twisting the barbed stem open (counterclockwise) or closed (clockwise). The jagged barb firmly secures 3/16″ ID sample tubing to the stem of the valve. |
||
Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
Wipe Sampler/Sampling media | |
---|---|
Bulk Method |
Device | Detector tube | Detector tube | Detector tube | Infrared spectrophotometer | Infrared spectrophotometer | CMS Chip |
---|---|---|---|---|---|---|
Model/Type | Gastec 2L | Dräger - Carbon dioxide 0.1%/a CH23501 | Matheson-Kitagawa 8014-126SA | Miran 1A & 1B | Miran 103 | Carbon dioxide, 1-20 Vol% range; Carbon dioxide, 1000-25000 ppm range; Carbon dioxide, 200-3000 ppm range |
Sampling information (see manufacturer instructions) |
0.13-6.0% vol | 0.5 - 6.0% vol | 0.1-2.6% vol | 0.4 ppm at 4.3 µm | 2%@4.45 µm |
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
---|---|---|---|---|---|---|---|
PEL-TWA |
5000 ppm (9000 mg/m³) |
REL-TWA |
5000 ppm (9000 mg/m³) |
TLV-TWA | PEL-TWA |
5000 ppm (9000 mg/m³) |
|
PEL-STEL | REL-STEL |
30,000 ppm (54,000 mg/m³) |
TLV-STEL | PEL-STEL |
30,000 ppm (54,000 mg/m³) |
||
PEL-C | REL-C | TLV-C | PEL-C | ||||
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Notes: | Notes: |
Notes:
Visit the ACGIH TLV site for specific data |
Notes:
See Section 5198. |
||||
Health factors: See NIH-NLM PubChem. | IDLH |
40,000 ppm |
|||||
Carcinogenic classifications: Not listed | Notes: | ||||||
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3: |
Additional Resources and Literature References
NOAA: CAMEO Chemicals - Carbon dioxide NIOSH: Pocket Guide to Chemical Hazards - Carbon dioxide Literature References
|
Last Updated Date : 05/23/2024