PERCHLOROETHYLENE (TETRACHLOROETHYLENE)†
CAS # | 127-18-4 |
---|---|
Formula |
C₂Cl₄ |
Synonyms |
tetrachloroethylene, carbon bichloride, 1,1,2,2-tetrachloroethylene, 1,1,2,2-tetrachloroethene |
Physical description | Colorless liquid with a mild, chloroform-like odor. | ||
---|---|---|---|
Boiling point | 250°F | Molecular weight | 165.8 |
Freezing point/melting point | -2°F | Vapor pressure | 14 mmHg |
Flash point | Vapor density | 5.83 | |
Specific gravity | 1.62 | Ionization potential | 9.32 eV |
Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
NFPA health rating | 2 | NFPA fire rating | 0 |
NFPA reactivity rating | 0 | NFPA special instruction | |
Vapor hazard ratio (VHR) | |||
Historical exceedance percentage | |||
Target organs |
Analyte code (IMIS no.) | 2020 | 2020 | |
---|---|---|---|
Sampling group | OVSG-1 | ||
Sampler/Sampling media | CSC tube (100/50 mg) [SKC 226-01] | SKC 575-002 Passive Sampler [SKC 575-002] | |
Sampling time* | 240 min (≥1 min Peak; ≤5 min C) |
<240 min TWA; >5min C, Peak |
|
Sampling volume (TWA)* | 12 L |
|
|
Sampling flow rate (TWA)* | 0.05 L/min |
|
|
Sampling volume (STEL/Peak/C)* | 0.05 L (Peak); 0.25 L (C) |
|
|
Sampling flow rate (STEL/Peak/C)* | 0.05 L/min |
|
|
Analytical method instruments | GC-FID | GC-FID | |
Method reference | OSHA 5000 (fully validated) | OSHA 1001 (fully validated) | |
Notes | To obtain sampling and analytical error similar to that available with active sampling, knowledge of the atmospheric pressure and temperature are required, and these should be obtained using NIST-traceable devices. If that is not possible, temperature is assumed to be 22.2 °C, and the atmospheric pressure is estimated based on the elevation of the sampling location. When estimates are used in place of traceable measurements the sampling and analytical error associated with passive sampling is substantially increased, and this makes it more difficult to demonstrate overexposures after considering the 95% lower confidence limit. |
||
Special requirements |
|
|
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
Wipe Sampler/Sampling media |
|
---|---|
Bulk Method |
|
Device | Detector tubes | Detector tubes | Detector tubes | Detector tubes | Detector tubes | CMS Chip |
---|---|---|---|---|---|---|
Model/Type | Dräger - Perchloroethylene 0.1/a, 8101551; 2/a, 8101501; 10/b, CH30701 | Gastec 133HA | Gastec 133L, 133LL | Gastec 133D | Matheson-Kitagawa 8014-135SA, 8014-243U, 8014-135SB, 8014-135SH | Perchloroethylene, 5-150 ppm range |
Sampling information (see manufacturer instructions) |
0.1/a: 3-9 strokes, 0.2-4 ppm range, uncertainty approx 33%. 2/a: 1-5 strokes, 2-300 ppm range, uncertainty approx 25%. 10/b: 3 strokes, 5-500 ppm range, uncertainty approx 25% | 4 strokes, 0.05-50 ppm range, uncertainty 16% for 0.2-10 ppm, 8% for 10-50 ppm | 0.5 - 2 strokes, 133L: 0.4-75 ppm range, uncertainty 16% for 2-5 ppm, 8% for 5-25 ppm. 133LL: 0.05-9 ppm range, uncertainty 16% for 0.2-1 ppm, 8% for 1-3 ppm | 1-8 hours, 3-150 ppm range, uncertainty 25% for 25-50 ppm-h, 16% for 50-150 ppm-h | follow mfr instructions. 8014-135SA: approx 5-300 ppm range, 8014-243U: approx 5-160 ppm range, 8014-135SB: approx 1-10 ppm, 8014-135SH: 0.05-2% range |
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
---|---|---|---|---|---|---|---|
PEL-TWA |
100 ppm |
REL-TWA |
|
TLV-TWA |
25 ppm [1990] |
PEL-TWA |
25 ppm (170 mg/m³) |
PEL-STEL |
|
REL-STEL |
|
TLV-STEL |
100 ppm [1990] |
PEL-STEL |
100 ppm (685 mg/m³) |
PEL-C |
200 ppm; 300 ppm (Peak) [a single time up to 5 min for any 3 hrs] |
REL-C |
|
TLV-C |
|
PEL-C |
300 ppm |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Notes:
See 29 CFR 1910.1000 Table Z-2. The Construction and Maritime PEL is 100 ppm (670 mg/m³) as an 8 hr TWA. See 29 CFR 1926.55 Table 1 and 29 CFR 1915.1000 Table Z-Shipyards. |
Notes:
CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION (LOQ 0.4 ppm). See Appendix A |
Notes:
BEI® |
Notes:
|
||||
Health factors: See NIH-NLM PubChem. | IDLH |
150 ppm |
|||||
Carcinogenic classifications: IARC-2A, NIOSH-Ca, NTP-R, TLV-A3 |
Notes:
Ca |
||||||
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
100 ppm/200 ppm/1000 ppm |
Additional Resources and Literature References
NOAA: CAMEO Chemicals - Perchloroethylene NIOSH: Pocket Guide to Chemical Hazards - Tetrachloroethylene Literature References
|
Last Updated Date : 06/06/2022