[Federal Register: April 28, 2010 (Volume 75, Number 81)][Notices] [Page 22424-22431]
From the Federal Register Online via GPO Access [wais.access.gpo.gov]
[DOCID:fr28ap10-89]
=======================================================================
-----------------------------------------------------------------------
DEPARTMENT OF LABOR
Occupational Safety and Health Administration
[Docket No. OSHA-2009-0005]
Avalotis Corp.; Grant of a Permanent Variance
AGENCY: Occupational Safety and Health Administration (OSHA),
Department of Labor.
ACTION: Notice of a grant of a permanent variance.
-----------------------------------------------------------------------
SUMMARY: This notice announces the grant of a permanent variance to
Avalotis Corp. ("the employer"). The permanent variance addresses the
provision that regulates the tackle used for boatswain's chairs (29 CFR
1926.452(o)(3)), as well as the provisions specified for personnel
hoists by paragraphs (c)(1) through (c)(4), (c)(8), (c)(13),
(c)(14)(i), and (c)(16) of 29 CFR 1926.552. As an alternative to
complying with these provisions, the employer may instead comply with
the conditions listed in this grant; these alternative conditions
regulate hoisting systems used during inside or outside chimney
construction to raise or lower workers in personnel cages, personnel
platforms, and boatswain's chairs between the bottom landing of a
chimney and an elevated work location. Accordingly, OSHA finds that
these alternative conditions protect workers at least as well as the
requirements specified by 29 CFR 1926.452(o)(3) and 1926.552(c)(1) through (c)(4),
(c)(8), (c)(13), (c)(14)(i), and (c)(16). This permanent variance
applies in Federal OSHA enforcement jurisdictions, and in those States
with OSHA-approved State Plans covering private-sector employers that
have identical standards and agree to the terms of the variance.
DATES: The effective date of the permanent variance is April 28, 2010.
FOR FURTHER INFORMATION CONTACT: General information and press
inquiries. For general information and press inquiries about this
notice, contact Jennifer Ashley, Director, OSHA Office of
Communications, Room N-3647, U.S. Department of Labor, 200 Constitution
Avenue, NW., Washington, DC 20210; telephone: (202) 693-1999.
Technical information. For technical information about this notice,
contact MaryAnn Garrahan, Director, Office of Technical Programs and
Coordination Activities, Room N-3655, OSHA, U.S. Department of Labor,
200 Constitution Avenue, NW., Washington, DC 20210; telephone: (202)
693-2110; fax: (202) 693-1644.
Copies of this Federal Register notice. Electronic copies of this
notice are available at http://www.regulations.gov. Electronic copies
of this notice, as well as news releases and other relevant
information, are available on OSHA's Web site at http://www.osha.gov.
SUPPLEMENTARY INFORMATION:
I. Background
In the past 36 years, a number of chimney construction companies
demonstrated to OSHA that several personnel hoist requirements (i.e.,
paragraphs (c)(1), (c)(2), (c)(3), (c)(4), (c)(8), (c)(13), (c)(14)(i),
and (c)(16) of 29 CFR 1926.552), as well as the tackle requirements for
boatswain's chairs (i.e., paragraph (o)(3) of 29 CFR 1926.452), result
in access problems that pose a serious danger to workers. These
companies requested permanent variances from these requirements, and
proposed alternative equipment and procedures to protect workers while
transporting them to and from their elevated worksites during chimney
construction and repair. The Agency subsequently granted these
companies permanent variances based on the proposed alternatives (see
38 FR 8545 (April 3, 1973), 44 FR 51352 (August 31, 1979), 50 FR 20145
(May 14, 1985), 50 FR 40627 (October 4, 1985), 52 FR 22552 (June 12,
1987), 68 FR 52961 (September 8, 2003), 70 FR 72659 (December 6, 2005),
71 FR 10557 (March 1, 2006), 72 FR 6002, 74 FR 34789 (July 17, 2009),
and 74 FR 41742 (August 18, 2009)).\1\
---------------------------------------------------------------------------
\1\ Zurn Industries, Inc. received two permanent variances from
OSHA. The first variance, granted on May 14, 1985 (50 FR 20145),
addressed the boatswain's-chair provision (then in paragraph (l)(5)
of 29 CFR 1926.451), as well as the hoist-platform requirements of
paragraphs (c)(1), (c)(2), (c)(3), and (c)(14)(i) of 29 CFR
1926.552. The second variance, granted on June 12, 1987 (52 FR
22552), includes these same paragraphs, as well as paragraphs
(c)(4), (c)(8), (c)(13), and (c)(16) of 29 CFR 1926.552.
---------------------------------------------------------------------------
Avalotis Corp. ("the employer") applied for a permanent variance
from the same personnel hoist- and boatswain's-chair requirements as
the previous companies, and proposed as an alternative to these
requirements the same equipment and procedures approved by OSHA in the
earlier variances. The Agency published the employer's variance
applications in the Federal Register on November 9, 2009 (74 FR 57704).
The employer constructs, remodels, repairs, maintains, inspects,
and demolishes tall chimneys made of reinforced concrete, brick, and
steel. This work, which occurs throughout the United States, requires
the employers to transport workers and construction material to and
from elevated work platforms and scaffolds located, respectively,
inside and outside tapered chimneys. While tapering contributes to the
stability of a chimney, it necessitates frequent relocation of, and
adjustments to, the work platforms and scaffolds so these structures
will fit the decreasing circumference of the chimney as construction
progresses upwards.
To transport workers to various heights inside and outside a
chimney, the employer proposed in its variance application to use a
hoist system that lifts and lowers personnel-transport devices that
include personnel cages, personnel platforms, or boatswain's chairs. In
this regard, the employer proposed to use personnel cages, personnel
platforms, or boatswain's chairs solely to transport workers with the
tools and materials necessary to do their work, and not to transport
only materials or tools on these devices in the absence of workers. In
addition, the employer proposed to attach a hopper or concrete bucket
to the hoist system to raise or lower material inside or outside a
chimney.
The employer also proposed to use a hoist engine, located and
controlled outside the chimney, to power the hoist system. The proposed
system consisted of a wire rope that: Spools off a winding drum (also
known as the hoist drum or rope drum) into the interior of the chimney;
passes to a footblock that redirects the rope from the horizontal to
the vertical planes; goes from the footblock through the overhead
sheaves above the elevated platform; and finally drops to the bottom
landing of the chimney where it connects to a personnel- or material-
transport device. A cathead, which is a superstructure at the top of
the system, supports the overhead sheaves. The overhead sheaves (and
the vertical span of the hoist system) move upward with the system as
chimney construction progresses. Two guide cables, suspended from the
cathead, eliminate swaying and rotation of the load. If the hoist rope
breaks, safety clamps activate and grip the guide cables to prevent the
load from falling. The employer proposed to use a headache ball,
located on the hoist rope directly above the load, to counterbalance
the rope's weight between the cathead sheaves and the footblock.
Additional conditions that the employer proposed to follow to
improve worker safety included:
Attaching the wire rope to the personnel cage using a
keyed-screwpin shackle or positive-locking link;
Adding limit switches to the hoist system to prevent
overtravel by the personnel- or material-transport devices;
Providing the safety factors and other precautions
required for personnel hoists specified by the pertinent provisions of
29 CFR 1926.552(c), including canopies and shields to protect workers
located in a personnel cage from material that may fall during hoisting
and other overhead activities;
Providing falling-object protection for scaffold platforms
as specified by 29 CFR 1926.451(h)(1);
Conducting tests and inspections of the hoist system as
required by 29 CFR 1926.20(b)(2) and 1926.552(c)(15);
Establishing an accident-prevention program that conforms
to 29 CFR 1926.20(b)(3);
Equipping workers who use a personnel cage, personnel
platform, or boatswain's chair with, and ensuring that they use,
personal fall arrest systems meeting the requirements of 29 CFR
1926.502(d);
Ensuring that workers using a personnel cage secure their
personal fall arrest system to an attachment point located inside the
cage, and that workers using personnel platforms or boatswain's chairs
secure their personal fall arrest systems to a vertical lifeline;
When using vertical lifelines, securing the lifelines to
the top of the chimney and weighting the lifelines properly, or
suitably affixing the lifelines to the bottom of the chimney, and
ensuring that workers remain attached to their lifeline during the
entire period of vertical transit;
Providing instruction to each worker who uses a personnel
platform or boatswain's chair regarding the shearing and struck-by
hazards posed by the hoist system (e.g., work platforms, scaffolds),
and the need to keep their limbs or other body parts clear of these
hazards during hoisting operations;
Providing the instruction on shearing and struck-by
hazards before a worker uses one of these personnel-transport devices
at the worksite; and periodically, and as necessary thereafter,
including whenever the worker demonstrates: a lack of knowledge about
the hazard or how to avoid it, a modification occurs to an existing
shearing hazard, or a new shearing hazard develops at the worksite;
Attaching a readily visible warning to each personnel
platform and boatswain's chair notifying workers in a language they
understand of potential shearing hazards during hoisting operations;
for warnings located on personnel platforms, using the following (or
equivalent) wording: "Warning--To avoid serious injury, keep your
hands, arms, feet, legs, and other parts of your body inside this
platform while it is in motion"; and for boatswain's chairs, the
warning uses the following (or equivalent) wording: "Warning--To avoid
serious injury, do not extend your hands, arms, feet, legs, or other
parts of your body from the side or to the front of this chair while it
is in motion; and
Establishing a clearly designated exclusion zone around
the hoist system's bottom landing and prohibiting any worker from
entering the exclusion zone except to access a personnel cage,
personnel platform, boatswain's chair, or material-transport device,
and then only when the personnel- and material- transport device is at
the bottom landing and not in operation.
II. Proposed Variance From 29 CFR 1926.452(o)(3)
The employer noted in its variance request that it is necessary, on
occasion, to use a boatswain's chair to transport workers to and from a
bracket scaffold on the outside of an existing chimney during flue
installation or repair work, or to transport them to and from an
elevated scaffold located inside a chimney that has a tapering
diameter. Paragraph (o)(3) of 29 CFR 1926.452, which regulates the
tackle used to rig a boatswain's chair, states that this tackle must
"consist of correct size ball bearings or bushed blocks containing
safety hooks and properly `eye-spliced' minimum five-eighth (\5/8\)
inch diameter first-grade manila rope [or equivalent rope]."
The primary purpose of this paragraph is to allow a worker to
safely control the ascent, descent, and stopping locations of the
boatswain's chair. However, the employer stated in its variance request
that, because of space limitations, the required tackle is difficult or
impossible to operate on some chimneys that are over 200 feet tall.
Therefore, as an alternative to complying with the tackle requirements
specified by 29 CFR 1926.452(o)(3), the employer proposed to use the
hoisting system described above in section I ("Background") of this
notice to raise or lower workers in a personnel cage to work locations
both inside and outside a chimney. In addition, the employer proposed
to use a personnel cage for this purpose to the extent that adequate
space is available, and to use a personnel platform only when using a
personnel cage was infeasible because of limited space. When available
space makes using a personnel platform infeasible, the employer
proposed to use a boatswain's chair to lift workers to work locations.
The proposed variance limited use of the boatswain's chair to
elevations above the last work location that the personnel platform can
reach; under these conditions, the employer proposed to attach the
boatswain's chair directly to the hoisting cable only when the
structural arrangement precludes the safe use of the block and tackle
required by 29 CFR 1926.452(o)(3).
III. Proposed Variance From 29 CFR 1926.552(c)
Paragraph (c) of 29 CFR 1926.552 specifies the requirements for
enclosed hoisting systems used to transport workers from one elevation
to another. This paragraph ensures that employers transport workers
safely to and from elevated work platforms by mechanical means during
the construction, alteration, repair, maintenance, or demolition of
structures such as chimneys. However, this standard does not provide
specific safety requirements for hoisting workers to and from elevated
work platforms and scaffolds in tapered chimneys; the tapered design
requires frequent relocation of, and adjustment to, the work platforms
and scaffolds. The space in a tapered chimney is not large enough or
configured so that it can accommodate an enclosed hoist tower.
Moreover, using an enclosed hoist tower for outside operations exposes
workers to additional fall hazards because they need to install extra
bridging and bracing to support a walkway between the hoist tower and
the tapered chimney.
Paragraph (c)(1) of 29 CFR 1926.552 requires employers to enclose
hoist towers located outside a chimney on the side or sides used for
entrance to, and exit from, the chimney; these enclosures must extend
the full height of the hoist tower. The employer asserted in its
proposed variance that it is impractical and hazardous to locate a
hoist tower outside tapered chimneys because it becomes increasingly
difficult, as a chimney rises, to erect, guy, and brace a hoist tower;
under these conditions, access from the hoist tower to the chimney or
to the movable scaffolds used in constructing the chimney exposes
workers to a serious fall hazard. Additionally, the employer noted that
the requirement to extend the enclosures 10 feet above the outside
scaffolds often exposes the workers involved in building these
extensions to dangerous wind conditions.
Paragraph (c)(2) of 29 CFR 1926.552 requires that employers enclose
all four sides of a hoist tower even when the tower is located inside a
chimney; the enclosure must extend the full height of the tower. In the
proposed variance, the employer contended that it is hazardous for
workers to erect and brace a hoist tower inside a chimney, especially
tapered chimneys or chimneys with sublevels, because these structures
have limited space and cannot accommodate hoist towers; space
limitations result from chimney design (e.g., tapering), as well as
reinforced steel projecting into the chimney from formwork that is near
the work location.
As an alternative to complying with the hoist-tower requirements of
29 CFR 1926.552(c)(1) and (c)(2), the employer proposed to use the
hoist system discussed in section I ("Background") of this notice to
transport workers to and from work locations inside and outside
chimneys. The employer claimed that this hoist system would make it
unnecessary for it to comply with other provisions of 29 CFR
1926.552(c) that specify requirements for hoist towers, including:
(c)(3)--Anchoring the hoist tower to a structure;
(c)(4)-Hoistway doors or gates;
(c)(8)--Electrically interlocking entrance doors or gates
that prevent hoist movement when the doors or gates are open;
(c)(13)--Emergency stop switch located in the car;
(c)(14)(i)--Using a minimum of two wire ropes for drum-
type hoisting; and
(c)(16)--Construction specifications for personnel hoists,
including materials assembly, structural integrity, and safety devices.
The employer asserted that the proposed hoisting system protected
workers at least as effectively as the personnel-hoist requirements of
29 CFR 1926.552(c).
IV. Comments on the Proposed Variance
OSHA received no comments on the proposed variance, including no
comments from State-Plan States and Territories.
V. Multi-State Variance
The variance applications stated that the employers perform chimney
work in a number of geographic locations in the United States, some of
which could include locations in one or more of the States and
Territories that operate OSHA-approved safety and health programs under
section 18 of the Occupational Safety and Health Act of 1970 ("State-
Plan States and Territories"; see 29 U.S.C. 651 et seq.). State-Plan
States and Territories have primary enforcement responsibility over the
work performed in those States and Territories. Under the provisions of
29 CFR 1952.9 ("Variances affecting multi-state employers") and 29
CFR 1905.14(b)(3) ("Actions on applications"), a permanent variance
granted by the Agency becomes effective in State-Plan States and
Territories as an authoritative interpretation of the applicants'
compliance obligation when: (1) The relevant standards are the same as
the Federal OSHA standards from which the applicants are seeking the
permanent variance; and (2) the State-Plan State or Territory does not
object to the terms of the variance application.
As noted in the previous section of this notice (section IV
("Comments on the Proposed Variance")), OSHA received no comments on
the variance application published in the Federal Register from any
State-Plan State or Territory. However, several State-Plan States and
Territories commented on earlier variance applications published in the
Federal Register involving the same standards and submitted by other
employers engaged in chimney construction and repair; OSHA is relying
on these previous comments to determine the position of these State-
Plan States and Territories on the variance applications submitted by
the present employers.\2\ The remaining paragraphs in this section
provide a summary of the positions taken by the State-Plan States and
Territories on the proposed alternative conditions.
---------------------------------------------------------------------------
\2\ See 68 FR 52961 (Oak Park Chimney Corp. and American Boiler
& Chimney Co.), 70 FR 72659 (International Chimney Corporation,
Karrena International, LLC, and Matrix Service Industrial
Contractors, Inc.), and 71 FR 10557 (Commonwealth Dynamics, Inc.,
Mid-Atlantic Boiler & Chimney, Inc., and R and P Industrial Chimney
Co., Inc.).
---------------------------------------------------------------------------
The following thirteen State-Plan States and one Territory have
standards identical to the Federal OSHA standards and agreed to accept
the alternative conditions: Alaska, Arizona, Indiana, Maryland,
Minnesota, Nevada, New Mexico, North Carolina, Oregon, Puerto Rico,
Tennessee, Vermont, Virginia, and Wyoming. Of the remaining 13 States
and Territories with OSHA-approved State plans, four of the States and
one Territory (Connecticut, Illinois, New Jersey, New York, and the
Virgin Islands) cover only public-sector workers and have no authority
over the private-sector workers addressed in this variance application
(i.e., that authority continues to reside with Federal OSHA).
Four States (Kentucky, Michigan, South Carolina, and Utah) accepted
the proposed alternative when specific additional requirements are
fulfilled. Kentucky noted that, while it agreed with the terms of the
variance, Kentucky statutory law requires affected employers to apply
to the State for a State variance. Michigan agreed to the alternative
conditions, but noted that its standards are not identical to the OSHA
standards covered by the variance application. Therefore, Michigan
cautioned that employers electing to use the variance in that State
must comply with several provisions in the Michigan standards that are
not addressed in the OSHA standard. South Carolina indicated that it
would accept the alternative conditions, but noted that, for the grant
of such a variance to be accepted by the South Carolina Commissioner of
Labor, the employers must file the grant at the Commissioner's office
in Columbia, South Carolina. Utah agreed to accept the Federal
variance, but requires the employers to contact the Occupational Safety
and Health Division, Labor Commission of Utah, regarding a procedural
formality that must be completed before implementing the variance in
that State.
California, Hawaii, Iowa, and Washington either had different
requirements in the affected standards or declined to accept the terms
of the variance. Therefore, the employers must apply separately for a
permanent variance from these four States.
Based on the responses previously received from State-Plan States
and Territories, the permanent Federal OSHA variance will be effective
in the following thirteen State-Plan States and one Territory: Alaska,
Arizona, Indiana, Maryland, Minnesota, Nevada, New Mexico, North
Carolina, Oregon, Puerto Rico, Tennessee, Virginia, Vermont, and
Wyoming; and in four additional states, Kentucky, Michigan, South
Carolina, and Utah, when the employers meet specific additional
requirements. However, this permanent variance does not apply in
California, Hawaii, Iowa, and Washington State. As stated earlier, in
the four States and one Territory (Connecticut, Illinois, New Jersey,
New York, and the Virgin Islands) that have State-Plan programs that
cover only public-sector workers, authority over the employers under
the permanent variance continues to reside with Federal OSHA.
VI. Decision
Avalotis Corp. seeks a permanent variance from the provision that
regulates the tackle used for boatswain's chairs (29 CFR
1926.452(o)(3)), as well as the provisions specified for personnel
hoists by paragraphs (c)(1) through (c)(4), (c)(8), (c)(13),
(c)(14)(i), and (c)(16) of 29 CFR 1926.552. Paragraph (o)(3) of 29 CFR
1926.452 states that the tackle used for boatswain's chairs must
"consist of correct size ball bearings or bushed blocks containing
safety hooks and properly `eye-spliced' minimum five-eighth (\5/8\)
inch diameter first-grade manila rope [or equivalent rope]." The
primary purpose of this provision is to allow a worker to safely
control the ascent, descent, and stopping locations of the boatswain's
chair. The proposed alternative to these requirements allows the
employer to use a boatswain's chair to lift workers to work locations
inside and outside a chimney when either a personnel cage or a
personnel platform is infeasible. The employer proposed to attach the
boatswain's chair to the hoisting system described as an alternative to
paragraph (c) of 29 CFR 1926.552.
Paragraph (c) of 29 CFR 1926.552 specifies the requirements for
enclosed hoisting systems used to transport personnel from one
elevation to another. This paragraph ensures that employers transport
workers safely to and from elevated work platforms by mechanical means
during construction work involving structures such as chimneys. In this
regard, paragraph (c)(1) of 29 CFR 1926.552 requires employers to
enclose hoist towers located outside a chimney on the side or sides
used for entrance to, and exit from, the structure; these enclosures
must extend the full height of the hoist tower. Under the requirements
of paragraph (c)(2) of 29 CFR 1926.552, employers must enclose all four
sides of a hoist tower located inside a chimney; these enclosures also
must extend the full height of the tower.
As an alternative to complying with the hoist-tower requirements of
29 CFR 1926.552(c)(1) and (c)(2), the employer proposed to use a hoist
system to transport workers to and from elevated work locations inside
and outside chimneys. The proposed hoist system includes a hoist
machine, cage, safety cables, and safety measures such as limit
switches to prevent overrun of the cage at the top and bottom landings,
and safety clamps that grip the safety cables if the main hoist line
fails. To transport workers to and from elevated work locations, the
employer proposed to attach a personnel cage to the hoist system.
However, when the employer can demonstrate that adequate space is not
available for the cage, it may use a personnel platform above the last
worksite that the cage can reach. Further, when the employer shows that
space limitations make it infeasible to use a work platform for
transporting workers, it may use a boatswain's chair above the last
worksite serviced by the personnel platform. Using the hoist system as
an alternative to the hoist-tower requirements of 29 CFR 1926.552(c)(1)
and (c)(2) eliminates the need to comply with the other provisions of
29 CFR 1926.552(c) that specify requirements for hoist towers.
Accordingly, the employer requested a permanent variance from these and
related provisions (i.e., paragraphs (c)(3), (c)(4), (c)(8), (c)(13),
(c)(14)(i), and (c)(16)).
Under section 6(d) of the Occupational Safety and Health Act of
1970 (29 U.S.C. 655), and based on the record discussed above, the
Agency finds that when the employer complies with the conditions of the
following order, the working conditions of the employer's workers will
be at least as safe and healthful as if the employers complied with the
working conditions specified by paragraph (o)(3) of 29 CFR 1926.452,
and paragraphs (c)(1) through (c)(4), (c)(8), (c)(13), (c)(14)(i), and
(c)(16) of 29 CFR 1926.552. This decision is applicable in all States
under Federal OSHA enforcement jurisdiction, and in the 13 State-Plan
States and one Territory with standards identical to the Federal
standards (Alaska, Arizona, Indiana, Maryland, Minnesota, Nevada, New
Mexico, North Carolina, Oregon, Puerto Rico, Tennessee, Virginia,
Vermont, and Wyoming). In Kentucky, Michigan, South Carolina and Utah,
the employers must meet additional conditions before this variance will
apply in those States. This decision does not apply in California,
Hawaii, Iowa, and Washington.
VII. Order
OSHA issues this order authorizing Avalotis Corp. ("the
employer") to comply with the following conditions instead of
complying with paragraph (o)(3) of 29 CFR 1926.452 and paragraphs
(c)(1) through (c)(4), (c)(8), (c)(13), (c)(14)(i), and (c)(16) of 29
CFR 1926.552. This order applies in Federal OSHA enforcement
jurisdictions, and in those States with OSHA-approved State plans that
have identical standards and have agreed to the terms of the variance.
1. Scope of the Permanent Variance
(a) This permanent variance applies only to tapered chimneys when
the employer uses a hoist system during inside or outside chimney
construction to raise or lower its workers between the bottom landing
of a chimney and an elevated work location on the inside or outside
surface of the chimney.
(b) When using a hoist system as specified in this permanent
variance, the employer must:
(i) Use the personnel cages, personnel platforms, or boatswain's
chairs raised and lowered by the hoist system solely to transport
workers with the tools and materials necessary to do their work; and
(ii) Attach a hopper or concrete bucket to the hoist system to
raise and lower all other materials and tools inside or outside a
chimney.
(c) Except for the requirements specified by 29 CFR 1926.452 (o)(3)
and 1926.552(c)(1) through (c)(4), (c)(8), (c)(13), (c)(14)(i), and
(c)(16), the employer must comply fully with all other applicable
provisions of 29 CFR parts 1910 and 1926.
2. Replacing a Personnel Cage With a Personnel Platform or a
Boatswain's Chair
(a) Personnel platform. When the employer demonstrates that
available space makes a personnel cage for transporting workers
infeasible, it may replace the personnel cage with a personnel platform
when it limits use of the personnel platform to elevations above the
last work location that the personnel cage can reach.
(b) Boatswain's chair. The employer must:
(i) Before using a boatswain's chair, demonstrate that available
space makes it infeasible to use a personnel platform for transporting
workers;
(ii) Limit use of a boatswain's chair to elevations above the last
work location that the personnel platform can reach; and
(iii) Use a boatswain's chair in accordance with block-and-tackle
requirements specified by 29 CFR 1926.452(o)(3), unless the employer
can demonstrate that the structural arrangement of the chimney
precludes such use.
3. Qualified Competent Person
(a) The employer must:
(i) Provide a qualified competent person, as specified in
paragraphs (f) and (m) of 29 CFR 1926.32, who is responsible for
ensuring that the design, maintenance, and inspection of the hoist
system comply with the conditions of this grant and with the
appropriate requirements of 29 CFR part 1926 ("Safety and Health
Regulations for Construction"); and
(ii) Ensure that the qualified competent person is present at
ground level to assist in an emergency whenever the hoist system is
raising or lowering workers.
(b) The employer must use a qualified competent person to design
and maintain the cathead described under Condition 8 ("Cathead and
Sheave"), below.
4. Hoist Machine
(a) Type of hoist. The employer must designate the hoist machine as
a portable personnel hoist.
(b) Raising or lowering a transport. The employer must ensure that:
(i) The hoist machine includes a base-mounted drum hoist designed
to control line speed; and
(ii) Whenever the employer raises or lowers a personnel or material
hoist (e.g., a personnel cage, personnel platform, boatswain's chair,
hopper, concrete bucket) using the hoist system:
(A) The drive components are engaged continuously when an empty or
occupied transport is being lowered (i.e., no "freewheeling");
(B) The drive system is interconnected, on a continuous basis,
through a torque converter, mechanical coupling, or an equivalent
coupling (e.g., electronic controller, fluid clutches, hydraulic
drives).
(C) The braking mechanism is applied automatically when the
transmission is in the neutral position and a forward-reverse coupling
or shifting transmission is being used; and
(D) No belts are used between the power source and the winding
drum.
(c) Power source. The employer must power the hoist machine by an
air, electric, hydraulic, or internal-combustion drive mechanism.
(d) Constant-pressure control switch. The employer must:
(i) Equip the hoist machine with a hand- or foot-operated constant-
pressure control switch (i.e., a "deadman control switch") that stops the
hoist immediately upon release; and
(ii) Protect the control switch to prevent it from activating if
the hoist machine is struck by a falling or moving object.
(e) Line-speed indicator. The employer must:
(i) Equip the hoist machine with an operating line-speed indicator
maintained in good working order; and
(ii) Ensure that the line-speed indicator is in clear view of the
hoist operator during hoisting operations.
(f) Braking systems. The employer must equip the hoist machine with
two (2) independent braking systems (i.e., one automatic and one
manual) located on the winding side of the clutch or couplings, with
each braking system being capable of stopping and holding 150 percent
of the maximum rated load.
(g) Slack-rope switch. The employer must equip the hoist machine
with a slack-rope switch to prevent rotation of the winding drum under
slack-rope conditions.
(h) Frame. The employer must ensure that the frame of the hoist
machine is a self-supporting, rigid, welded-steel structure, and that
holding brackets for anchor lines and legs for anchor bolts are
integral components of the frame.
(i) Stability. The employer must secure hoist machines in position
to prevent movement, shifting, or dislodgement.
(j) Location. The employer must:
(i) Locate the hoist machine far enough from the footblock to
obtain the correct fleet angle for proper spooling of the cable on the
drum; and
(ii) Ensure that the fleet angle remains between one-half degree
(\1/2\[deg]) and one and one-half degrees (1\1/2\[deg]) for smooth
drums, and between one-half degree (\1/2\[deg]) and two degrees
(2[deg]) for grooved drums, with the lead sheave centered on the
drum.\3\
---------------------------------------------------------------------------
\3\ This variance adopts the definition of, and specifications
for, fleet angle from Cranes and Derricks, H. I. Shapiro, et al.
(eds.); New York: McGraw-Hill; 3rd ed., 1999, page 592. Accordingly,
the fleet angle is "[t]he angle the rope leading onto a [winding]
drum makes with the line perpendicular to the drum rotating axis
when the lead rope is making a wrap against the flange."
---------------------------------------------------------------------------
(k) Drum and flange diameter. The employer must:
(i) Provide a winding drum for the hoist that is at least 30 times
the diameter of the rope used for hoisting; and
(ii) Ensure that the winding drum has a flange diameter that is at
least one and one-half (1\1/2\) times the winding-drum diameter.
(l) Spooling of the rope. The employer must never spool the rope
closer than two (2) inches (5.1 cm) from the outer edge of the winding-
drum flange.
(m) Electrical system. The employer must ensure that all electrical
equipment is weatherproof.
(n) Limit switches. The employer must equip the hoist system with
limit switches and related equipment that automatically prevent
overtravel of a personnel cage, personnel platform, boatswain's chair,
or material-transport device at the top of the supporting structure and
at the bottom of the hoistway or lowest landing level.
5. Methods of Operation
(a) Employee qualifications and training. The employer must:
(i) Ensure that only trained and experienced workers, who are
knowledgeable of hoist-system operations, control the hoist machine;
and
(ii) Provide instruction, periodically, and as necessary, on how to
operate the hoist system, to each worker who uses a personnel cage for
transportation.
(b) Speed limitations. The employer must not operate the hoist at a
speed in excess of:
(i) Two hundred and fifty (250) feet (76.9 m) per minute when a
personnel cage is being used to transport workers;
(ii) One hundred (100) feet (30.5 m) per minute when a personnel
platform or boatswain's chair is being used to transport workers; or
(iii) A line speed that is consistent with the design limitations
of the system when only material is being hoisted.
(c) Communication. The employer must:
(i) Use a voice-mediated intercommunication system to maintain
communication between the hoist operator and the workers located in or
on a moving personnel cage, personnel platform, or boatswain's chair;
(ii) Stop hoisting if, for any reason, the communication system
fails to operate effectively; and
(iii) Resume hoisting only when the site superintendent determines
that it is safe to do so.
6. Hoist Rope
(a) Grade. The employer must use a wire rope for the hoist system
(i.e., "hoist rope") that consists of extra-improved plow steel, an
equivalent grade of non-rotating rope, or a regular lay rope with a
suitable swivel mechanism.
(b) Safety factor. The employer must maintain a safety factor of at
least eight (8) times the safe workload throughout the entire length of
hoist rope.
(c) Size. The employer must use a hoist rope that is at least one-
half (\1/2\) inch (1.3 cm) in diameter.
(d) Inspection, removal, and replacement. The employer must:
(i) Thoroughly inspect the hoist rope before the start of each job
and on completing a new setup;
(ii) Maintain the proper diameter-to-diameter ratios between the
hoist rope and the footblock and the sheave by inspecting the wire rope
regularly (see Conditions 7(c) and 8(d), below); and
(iii) Remove and replace the wire rope with new wire rope when any
of the conditions specified by 29 CFR 1926.552(a)(3) occurs.
(e) Attachments. The employer must attach the rope to a personnel
cage, personnel platform, or boatswain's chair with a keyed-screwpin
shackle or positive-locking link.
(f) Wire-rope fastenings. When the employer uses clip fastenings
(e.g., U-bolt wire-rope clips) with wire ropes, it must:
(i) Use Table H-20 of 29 CFR 1926.251 to determine the number and
spacing of clips;
(ii) Use at least three (3) drop-forged clips at each fastening;
(iii) Install the clips with the "U" of the clips on the dead end
of the rope; and
(iv) Space the clips so that the distance between them is six (6)
times the diameter of the rope.
7. Footblock
(a) Type of block. The employer must use a footblock:
(i) Consisting of construction-type blocks of solid single-piece
bail with a safety factor that is at least four (4) times the safe
workload, or an equivalent block with roller bearings;
(ii) Designed for the applied loading, size, and type of wire rope
used for hoisting;
(iii) Designed with a guard that contains the wire rope within the
sheave groove;
(iv) Bolted rigidly to the base; and
(v) Designed and installed so that it turns the moving wire rope to
and from the horizontal or vertical direction as required by the
direction of rope travel.
(b) Directional change. The employer must ensure that the angle of
change in the hoist rope from the horizontal to the vertical direction
at the footblock is approximately 90[deg].
(c) Diameter. The employer must ensure that the line diameter of
the footblock is at least 24 times the diameter of the hoist rope.
8. Cathead and Sheave
(a) Support. The employer must use a cathead (i.e., "overhead
support") that consists of a wide-flange beam, or two (2) steel-channel
sections securely bolted back-to-back to prevent spreading.
(b) Installation. The employer must ensure that:
(i) All sheaves revolve on shafts that rotate on bearings; and
(ii) The bearings are mounted securely to maintain the proper
bearing position at all times.
(c) Rope guides. The employer must provide each sheave with
appropriate rope guides to prevent the hoist rope from leaving the
sheave grooves when the rope vibrates or swings abnormally.
(d) Diameter. The employer must use a sheave with a diameter that
is at least 24 times the diameter of the hoist rope.
9. Guide Ropes
(a) Number and construction. The employer must affix two (2) guide
ropes by swivels to the cathead. The guide ropes must:
(i) Consist of steel safety cables not less than one-half (\1/2\)
inch (1.3 cm) in diameter; and
(ii) Be free of damage or defects at all times.
(b) Guide rope fastening and alignment tension. The employer must
fasten one end of each guide rope securely to the overhead support,
with appropriate tension applied at the foundation.
(c) Height. The employer must rig the guide ropes along the entire
height of the hoist-machine structure.
10. Personnel Cage
(a) Construction. A personnel cage must be of steel-frame
construction and capable of supporting a load that is four (4) times
its maximum rated load capacity. The employer also must ensure that the
personnel cage has:
(i) A top and sides that are permanently enclosed (except for the
entrance and exit);
(ii) A floor securely fastened in place;
(iii) Walls that consist of 14-gauge, one-half (\1/2\) inch (1.3
cm) expanded metal mesh, or an equivalent material;
(iv) Walls that cover the full height of the personnel cage between
the floor and the overhead covering;
(v) A sloped roof constructed of one-eighth (\1/8\) inch (0.3 cm)
aluminum, or an equivalent material;
(vi) Safe handholds (e.g., rope grips--but not rails or hard
protrusions \4\) that accommodate each occupant; and
---------------------------------------------------------------------------
\4\ To reduce impact hazards should workers lose their balance
because of cage movement.
---------------------------------------------------------------------------
(vii) Attachment points to which workers secure their personal fall
protection systems.
(b) Overhead weight. A personnel cage must have an overhead weight
(e.g., a headache ball of appropriate weight) to compensate for the
weight of the hoist rope between the cathead and the footblock. In
addition, the employer must:
(i) Ensure that the overhead weight is capable of preventing line
run; and
(ii) Use a means to restrain the movement of the overhead weight so
that the weight does not interfere with safe personnel hoisting.
(c) Gate. The personnel cage must have a gate that:
(i) Guards the full height of the entrance opening; and
(ii) Has a functioning mechanical lock that prevents accidental
opening.
(d) Operating procedures. The employer must post the procedures for
operating the personnel cage conspicuously at the hoist operator's
station.
(e) Capacity. The employer must:
(i) Hoist no more than four (4) occupants in the cage at any one
time; and
(ii) Ensure that the rated load capacity of the cage is at least
250 pounds (113.4 kg) for each occupant so hoisted.
(f) Worker notification. The employer must post a sign in each
personnel cage notifying workers of the following conditions:
(i) The standard rated load, as determined by the initial static
drop test specified by Condition 10(g) ("Static drop tests"), below;
and
(ii) The reduced rated load for the specific job.
(g) Static drop tests. The employer must:
(i) Conduct static drop tests of each personnel cage that comply
with the definition of "static drop test" specified by section 3
("Definitions") and the static drop test procedures provided in
section 13 ("Inspections and Tests") of American National Standards
Institute (ANSI) standard A10.22-1990 (R1998) ("American National
Standard for Rope-Guided and Non-guided Worker's Hoists--Safety
Requirements");
(ii) Perform the initial static drop test at 125 percent of the
maximum rated load of the personnel cage, and subsequent drop tests at
no less than 100 percent of its maximum rated load; and
(iii) Use a personnel cage for raising or lowering workers only
when no damage occurred to the components of the cage as a result of
the static drop tests.
11. Safety Clamps
(a) Fit to the guide ropes. The employer must:
(i) Fit appropriately designed and constructed safety clamps to the
guide ropes; and
(ii) Ensure that the safety clamps do not damage the guide ropes
when in use.
(b) Attach to the personnel cage. The employer must attach safety
clamps to each personnel cage for gripping the guide ropes.
(c) Operation. The safety clamps attached to the personnel cage
must:
(i) Operate on the "broken rope principle" defined in section 3
("Definitions") of ANSI standard A10.22-1990 (R1998);
(ii) Be capable of stopping and holding a personnel cage that is
carrying 100 percent of its maximum rated load and traveling at its
maximum allowable speed if the hoist rope breaks at the footblock; and
(iii) Use a pre-determined and pre-set clamping force (i.e., the
"spring compression force") for each hoist system.
(d) Maintenance. The employer must keep the safety clamp assemblies
clean and functional at all times.
12. Overhead Protection
(a) The employer must install a canopy or shield over the top of
the personnel cage that is made of steel plate at least three-
sixteenths (3/16) of an inch (4.763 mm) thick, or material of
equivalent strength and impact resistance, to protect workers (i.e.,
both inside and outside the chimney) from material and debris that may
fall from above.
(b) The employer must ensure that the canopy or shield slopes to
the outside of the personnel cage.\5\
---------------------------------------------------------------------------
\5\ Paragraphs (a) and (b) were adapted from OSHA's Underground
Construction standard (29 CFR 1926.800(t)(4)(iv)).
---------------------------------------------------------------------------
13. Emergency-Escape Device
(a) Location. The employer must provide an emergency-escape device
in at least one of the following locations:
(i) In the personnel cage, provided that the device is long enough
to reach the bottom landing from the highest possible escape point; or
(ii) At the bottom landing, provided that a means is available in
the personnel cage for the occupants to raise the device to the highest
possible escape point.
(b) Operating instructions. The employer must ensure that written
instructions for operating the emergency-escape device are attached to
the device.
(c) Training. The employer must instruct each worker who uses a
personnel cage for transportation on how to operate the emergency-
escape device:
(i) Before the worker uses a personnel cage for transportation; and
(ii) Periodically, and as necessary, thereafter.
14. Personnel Platforms
(a) Personnel platforms. When the employer elects to replace the
personnel cage with a personnel platform in accordance with Condition
2(a) of this variance, it must:
(i) Ensure that an enclosure surrounds the platform, and that this
enclosure is at least 42 inches (106.7 cm) above the platform's floor;
(ii) Provide overhead protection when an overhead hazard is, or
could be, present; and
(iii) Comply with the applicable scaffolding strength requirements
specified by 29 CFR 1926.451(a)(1).
15. Protecting Workers From Fall and Shearing Hazards
(a) Fall hazards. The employer must:
(i) Before workers use personnel cages, personnel platforms, or
boatswain's chairs, equip the workers with, and ensure that they use,
personal fall arrest systems that meet the requirements of 29 CFR
1926.502(d);
(ii) Ensure that workers using personnel cages secure their fall
arrest systems to attachment points located inside the cage;
(iii) Ensure that workers using personnel platforms and boatswain's
chairs secure their personal fall arrest systems to a vertical
lifeline; and
(iv) When using vertical lifelines:
(A) Secure the lifelines to the top of the chimney;
(B) Weight the lifelines properly, or suitably affix the lifelines
to the bottom of the chimney; and
(C) Ensure that workers remain attached to their lifeline during
the entire period of vertical transit.
(b) Shearing hazards. The employer must:
(i) Provide workers who use personnel platforms or boatswain's
chairs with instruction on the shearing hazards posed by the hoist
system (e.g., work platforms, scaffolds), and the need to keep their
limbs or other body parts clear of these hazards during hoisting
operations;
(ii) Provide the instruction on shearing and struck-by hazards:
(A) Before a worker uses a personnel platform or boatswain's chair
at the worksite; and
(B) Periodically, and as necessary, thereafter, including whenever
a worker demonstrates a lack of knowledge about the hazards or how to
avoid the hazards, a modification occurs to an existing shearing or
struck-by hazard, or a new shearing or struck-by hazard develops at the
worksite; and
(iii) Attach a readily visible warning to each personnel platform
and boatswain's chair notifying workers in a language they understand
of potential shearing hazards they may encounter during hoisting
operations, and that uses the following (or equivalent) wording:
(A) For personnel platforms: "Warning--To avoid serious injury,
keep your hands, arms, feet, legs, and other parts of your body inside
this platform while it is in motion"; and
(B) For boatswain's chairs: "Warning--To avoid serious injury, do
not extend your hands, arms, feet, legs, or other parts your body from
the side or to the front of this chair while it is in motion."
16. Exclusion Zone
The employer must:
(a) Establish a clearly designated exclusion zone around the bottom
landing of the hoist system; and
(b) Prohibit any worker from entering the exclusion zone except to
access a personnel- or material-transport device, and then only when
the device is at the bottom landing and not in operation (i.e., when
the drive components of the hoist machine are disengaged and the
braking mechanism is properly applied).
17. Inspections, Tests, and Accident Prevention
(a) The employer must:
(i) Conduct inspections of the hoist system as required by 29 CFR
1926.20(b)(2);
(ii) Ensure that a competent person conducts daily visual
inspections of the hoist system; and
(iii) Inspect and test the hoist system as specified by 29 CFR
1926.552(c)(15).
(b) The employer must comply with the accident-prevention
requirements of 29 CFR 1926.20(b)(3).
18. Welding
(a) The employer must use only qualified welders to weld components
of the hoisting system.
(b) The employer must ensure that the qualified welders:
(i) Are familiar with the weld grades, types, and materials
specified in the design of the system; and
(ii) Perform the welding tasks in accordance with 29 CFR 1926,
subpart J ("Welding and Cutting").
19. OSHA Notification
(a) At least 15 calendar days prior to commencing any chimney
construction operation using the conditions specified herein, the
employer must notify the OSHA Area Office nearest to the worksite, or
the appropriate State Plan Office, of the operation, including the
location of the operation and the date that the operation will
commence.
(b) The employer must inform OSHA national headquarters as soon as
it has knowledge that it will:
(i) Cease to do business; or
(ii) Transfer the activities covered by this permanent variance to
a successor company.
VIII. Authority and Signature
David Michaels, PhD, MPH, Assistant Secretary of Labor for
Occupational Safety and Health, U.S. Department of Labor, 200
Constitution Ave., NW., Washington, DC, directed the preparation of
this notice. OSHA is issuing this notice under the authority specified
by Section 6(d) of the Occupational Safety and Health Act of 1970 (29
U.S.C. 655), Secretary of Labor's Order No. 5-2007 (72 FR 31160), and
29 CFR part 1905.
Signed at Washington, DC, on April 22, 2010.
David Michaels,
Assistant Secretary of Labor for Occupational Safety and Health.
[FR Doc. 2010-9785 Filed 4-27-10; 8:45 am]