1
06/19/2014 - 1926.760(d)(1) - Clarification regarding hazard access zones in steel erection
2
04/22/2011 - 1926.760(c) - Distance at which fall protection is required for steel erection activities.
3
04/22/2011 - 1926.760(a) - Distance at which fall protection is required for steel erection activities.
4
04/22/2011
- 1926.760, 1926.760(a), 1926.760(c) -
Distance at which fall protection is required for steel erection activities.
5
08/10/2010 - 1926.760(c)(3) - Acceptable equivalent to control lines for a Controlled Decking Zone (CDZ) in steel erection activities. 29 CFR 1926.760(c)(3).
6
08/10/2010
- 1926.760, 1926.760(c)(3) -
Acceptable equivalent to control lines for a Controlled Decking Zone (CDZ) in steel erection activities. 29 CFR 1926.760(c)(3).
7
03/02/2010 - 1926.760(a)(1) - Whether an employer can use a controlled access zone during curtain wall installation.
8
03/02/2010
- 1926.760, 1926.760(a)(1) -
Whether an employer can use a controlled access zone during curtain wall installation.
9
04/05/2005 - 1926.760(a)(3) - Evaluation if moving point-to-point on concrete wall to make initial connections of structural steel is "connecting" work; landing loads on systems-engineered metal building.
10
04/05/2005 - 1926.760(a)(13) - Evaluation if moving point-to-point on concrete wall to make initial connections of structural steel is "connecting" work; landing loads on systems-engineered metal building.
11
04/05/2005 - 1926.760(a)(1) - Evaluation if moving point-to-point on concrete wall to make initial connections of structural steel is "connecting" work; landing loads on systems-engineered metal building.
12
04/05/2005 - 1926.760(a) - Evaluation if moving point-to-point on concrete wall to make initial connections of structural steel is "connecting" work; landing loads on systems-engineered metal building.
13
04/05/2005 - 1926.760(b)(3) - Evaluation if moving point-to-point on concrete wall to make initial connections of structural steel is "connecting" work; landing loads on systems-engineered metal building.
14
04/05/2005 - 1926.760(b)(1) - Evaluation if moving point-to-point on concrete wall to make initial connections of structural steel is "connecting" work; landing loads on systems-engineered metal building.
15
04/05/2005 - 1926.760(b) - Evaluation if moving point-to-point on concrete wall to make initial connections of structural steel is "connecting" work; landing loads on systems-engineered metal building.
16
04/05/2005
- 1926.760, 1926.760(a), 1926.760(a)(1), 1926.760(a)(13), 1926.760(a)(3), 1926.760(b), 1926.760(b)(1), 1926.760(b)(3) -
Evaluation if moving point-to-point on concrete wall to make initial connections of structural steel is "connecting" work; landing loads on systems-engineered metal building.
17
08/03/2004 - 1926.760(c) - Use of fall protection by deaf employees performing steel erection activities.
18
08/03/2004 - 1926.760(b) - Use of fall protection by deaf employees performing steel erection activities.
19
08/03/2004 - 1926.760(a)(3) - Use of fall protection by deaf employees performing steel erection activities.
20
08/03/2004 - 1926.760(a)(1) - Use of fall protection by deaf employees performing steel erection activities.
21
08/03/2004
- 1926.760, 1926.760(a)(1), 1926.760(a)(3), 1926.760(b), 1926.760(c) -
Use of fall protection by deaf employees performing steel erection activities.
22
03/04/2004 - 1926.760(d) - Wire rope clips on suspension scaffolds; safety latches on large crane hooks; order of assembly for hanging scaffolds; and horizontal lifeline design.
23
12/22/2003 - 1926.760(c)(5) - Designation of an entire floor as a controlled decking zone for steel decking work.
24
12/22/2003 - 1926.760(c)(3) - Designation of an entire floor as a controlled decking zone for steel decking work.
25
12/22/2003 - 1926.760(c) - Designation of an entire floor as a controlled decking zone for steel decking work.
26
12/22/2003
- 1926.760, 1926.760(c), 1926.760(c)(3), 1926.760(c)(5) -
Designation of an entire floor as a controlled decking zone for steel decking work.
27
09/26/2003 - 1926.760(c)(3) - Compliance of using warning lines and/or control access zones for fall protection on roofs with a slope greater than 4:12.
28
09/26/2003
- 1926.760, 1926.760(c)(3) -
Compliance of using warning lines and/or control access zones for fall protection on roofs with a slope greater than 4:12.
29
08/26/2003 - 1926.760(a)(2) - Requirements for perimeter columns and perimeter safety cables in the Steel Erection standard.
30
07/21/2003 - 1926.760(a)(3) - Permissibility of using guardrail systems other than perimeter safety cables in steel erection.
31
07/21/2003 - 1926.760(a)(2) - Permissibility of using guardrail systems other than perimeter safety cables in steel erection.
32
07/21/2003 - 1926.760(a)(1) - Permissibility of using guardrail systems other than perimeter safety cables in steel erection.
33
07/07/2003
- 1926.760 -
Requirements for fall protection when ladder jack scaffolds are used for residential and commercial construction
34
04/09/2003 - 1926.760(a)(3) - OSHA standards set minimum safety and health requirements;they do not prohibit employers from adopting more stringent requirements.
35
04/09/2003 - 1926.760(c) - OSHA standards set minimum safety and health requirements;they do not prohibit employers from adopting more stringent requirements.
36
04/09/2003 - 1926.760(b) - OSHA standards set minimum safety and health requirements;they do not prohibit employers from adopting more stringent requirements.
37
04/09/2003 - 1926.760(a)(1) - OSHA standards set minimum safety and health requirements;they do not prohibit employers from adopting more stringent requirements.
38
04/09/2003 - 1926.760(a) - OSHA standards set minimum safety and health requirements;they do not prohibit employers from adopting more stringent requirements.
39
04/09/2003
- 1926.760, 1926.760(a), 1926.760(a)(1), 1926.760(b), 1926.760(c), 1926.760(a)(3) -
OSHA standards set minimum safety and health requirements;they do not prohibit employers from adopting more stringent requirements.
40
11/08/2002 - 1926.760(d)(2) - Applicability of the steel erection standard to repair and installation of metal roofing and roofing accessories.
41
11/08/2002 - 1926.760(c) - Applicability of the steel erection standard to repair and installation of metal roofing and roofing accessories.
42
07/17/2002 - 1926.760(a)(2) - Steel erection standard requirements concerning installation of perimeter safety cable.
43
07/17/2002 - 1926.760(d)(3) - Steel erection standard requirements concerning installation of perimeter safety cable.
44
07/17/2002 - 1926.760(d) - Steel erection standard requirements concerning installation of perimeter safety cable.
45
01/30/2002 - 1926.760(e) - Clarification of "Controlling Contractor" duties under the Steel Erection Standard (1926 Subpart R)
46
12/21/2001
- 1926.760 -
Decision to release the new compliance directive for the steel erection standard in draft form.
47
09/27/2001
- 1926.760 -
History and background of the Steel Erection Final Rule.
48
09/18/2001 - 1926.760(e) - Fall protection requirements of various construction (1926) standards.
49
09/18/2001 - 1926.760(d)(3) - Fall protection requirements of various construction (1926) standards.
50
09/18/2001 - 1926.760(c)(3) - Fall protection requirements of various construction (1926) standards.
51
09/18/2001 - 1926.760(c) - Fall protection requirements of various construction (1926) standards.
52
09/18/2001 - 1926.760(b)(3) - Fall protection requirements of various construction (1926) standards.
53
09/18/2001 - 1926.760(a)(2) - Fall protection requirements of various construction (1926) standards.
54
03/13/1995 - 1926.760(a)(1) - New Fall Protection standards and standards for scaffolds used during dry wall work