OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can consult OSHA's website at https://www.osha.gov.

May 4, 1987

Mr. Peter E. Kelly
Director of Safety and
Health
Timber Products Manufacturers
951 East Third Avenue
Spokane, Washington 99202

Dear Mr. Kelly:

This is in response to your letter of April 14 regarding your company's labeling system which was designed to meet the requirements of the Occupational Safety and Health Administration's (OSHA) Hazard Communication Standard.

The Hazard Communication Standard requires employers to label each container of hazardous chemicals in the workplace with the following information:

(i) Identity of the hazardous chemical (s) contained therein; and

(ii) Appropriate hazard warnings.

In addition, if containers of hazardous chemicals are shipped, the name and address of the chemical manufacturer, importer, or other responsible party must also appear on the label.

The standard's preamble also recognizes the existence of the numerous labeling systems that are currently in use in industry. The intent of the standard is to permit the use of these systems as long as the employer's entire Hazard Communication Program (HCP) is effective. In assessing an employer's compliance with the standard, an OSHA compliance officer will evaluate the effectiveness of the employer's inplant labeling system through a review of the employer's material safety data sheets and training program. An effective program would be one that ensures that employees are aware of the hazardous effects of the chemicals they may be exposed to as well as meeting the other basic requirements of the standard. Hazard warnings used as part of inplant labeling systems, in combination with the HCP, are deemed to be effective when they promote safe handling and use of hazardous chemicals in the workplace.

From the label decal enclosed with your letter it appears that the chemical identity and health hazard warnings appear, in addition to a numerical hazard rating system. As long as the hazard warnings and/or ratings are correctly selected it appears your labeling system would meet the inplant labeling requirements of the Hazard Communication Standard. Please note that for shipped containers your labeling system could not rely on a numerical rating system and would have to be supplemented with the appropriate hazard warning(s) in a narrative form and include the target organ effect as well as the physical hazards of the chemicals.

If you have any further questions, please feel free to contact us again.

Sincerely,



John A. Pendergrass
Assistant Secretary