Inspection Detail
Inspection: 1225261.015 - Fisher Controls
Inspection Information - Office: Iowa 0751910
Site Address:
Fisher Controls
1702 S 12th Avenue
Marshalltown, IA 50158
Mailing Address:
1702 S 12th Avenue, Marshalltown, IA 50158
Union Status: Union
SIC:
NAICS: 332911/Industrial Valve Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/14/2017
Emphasis:
Case Closed: 12/06/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1202148 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $10,800 | $0 | $0 | $0 | $0 | $10,800 |
Current Penalty | $6,300 | $0 | $0 | $0 | $0 | $6,300 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 88.4 - CODE OF IOWA (2017) | 05/24/2017 | 12/09/2018 | $6,300 | $6,300 | $0 | 06/14/2017 | F - Formal Settlement | |
2. | 01002 | Serious | 19100028 B01 I | 05/24/2017 | 06/20/2017 | $0 | $4,500 | $0 | 06/19/2017 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At 7:30 p.m. on April 13, 2017, an employee was checking air tank for leaks. The employee had not removed 125 psi air pressure from tank and was struck in their head by the pipe plug when it blew off from the tank.
Keywords: Head, Pipe Plug, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1225261.015 | 61 | M | Fatality | Assemblers |