Inspection Detail
Inspection: 1389906.015 - South Texas Illumination Llc
Inspection Information - Office: Houston South Area Office
Site Address:
South Texas Illumination Llc
W Fwy Blvd S - I-10 Feeder Eastbound At S. Peacock St.
Vidor, TX 77662
Mailing Address:
14308 State Highway 155 N, Winona, TX 75792
Union Status: NonUnion
SIC:
NAICS: 237310/ Highway, Street, and Bridge Construction
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/29/2019
Emphasis:
Case Closed: 05/13/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1441014 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 2 | 5 | |||
Current Violations | 3 | 2 | 5 | |||
Initial Penalty | $23,868 | $0 | $0 | $1,488 | $0 | $25,356 |
Current Penalty | $14,321 | $0 | $0 | $893 | $0 | $15,214 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260251 E08 | 07/23/2019 | 08/23/2019 | $3,182 | $5,304 | $0 | I - Informal Settlement | ||
2. | 01002A | Serious | 19261408 A01 | 07/23/2019 | 08/23/2019 | $5,569 | $9,282 | $0 | I - Informal Settlement | ||
3. | 01002B | Serious | 19261408 A02 | 07/23/2019 | 08/23/2019 | $0 | $0 | $0 | I - Informal Settlement | ||
4. | 01002C | Serious | 19261408 A02 III B | 07/23/2019 | 08/23/2019 | $0 | $0 | $0 | I - Informal Settlement | ||
5. | 01003 | Serious | 19261427 A02 | 07/23/2019 | 08/23/2019 | $5,569 | $9,282 | $0 | I - Informal Settlement | ||
6. | 02001 | Other | 19261412 E03 I | 07/23/2019 | 08/23/2019 | $446 | $744 | $0 | I - Informal Settlement | ||
7. | 02002 | Other | 19261412 F02 | 07/23/2019 | $446 | $744 | $0 | I - Informal Settlement |
Investigation Summary
At 5:10 p.m. on March 28, 2019, an employee was working on a crew that was tasked with pouring a cement foundation for high mast light poles. The employee was standing/sitting on the rear of a boom truck as the boom truck operator removed a 41.83 foot tremie pipe used to pour the cement. As the pipe was laid on the ground, the boom contacted a 7,620 Volt overhead power line. The boom truck was energized and the employee was electrocuted.
Keywords: Boom, Construction, Electrocuted, Overhead Power Line
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1389906.015 | 32 | M | Fatality | Construction laborers |