Inspection Detail
Inspection: 1415159.015 - Exotic Performance Engineering Inc.
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Exotic Performance Engineering Inc.
10788 Sw 188th Street
Cutler Bay, FL 33157
Mailing Address:
10788 Sw 188th Street, Cutler Bay, FL 33157
Union Status: NonUnion
SIC:
NAICS: 541330/Engineering Services
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 07/15/2019
Emphasis:
Case Closed: 03/11/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1475805 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19101000 A02 | 01/10/2020 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 10:00 a.m. on July 13, 2019, Employee #1 was operating a propane powered concrete floor grinder. There was no ventilation in the area. The carbon monoxide built up, causing the death of the employee due to lack of oxygen.
Keywords: Carbon Monoxide, Grinder, Overexposure, Propane, Ventilation
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1415159.015 | 44 | M | Fatality | Garage and service station related occupations |