Inspection Detail
Inspection: 1542164.015 - Pm Engineered Solutions Inc.
Inspection Information - Office: Hartford Area Office
Site Address:
Pm Engineered Solutions Inc.
140 Commercial Street
Watertown, CT 06795
Mailing Address:
140 Commercial Street, Watertown, CT 06795
Union Status: NonUnion
SIC:
NAICS: 332117/Powder Metallurgy Part Manufacturing
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/05/2022
Emphasis: N:Dustexpl, L:Fall, L:Forklift
Case Closed: 11/12/2024
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1787458 | ||
Referral | 1786612 | Yes |
Investigation Summary
At 1:00 p.m. on July 14, 2019, an employee was energizing a portable heater to verify that repairs had corrected reported issues with the machine. The employee contacted live 480 volt terminal screws inside of the control compartment of the machine. The employee was killed when he was electrocuted.
Keywords: Contact, Electric Conductor, Electric Shock, Electric current, Electrocuted, Energized, Glove, Hand, Heater, Maintenance, PPE, Repair, Shock
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1542164.015 | 46 | M | Fatality | Machinery maintenance occupations |