Inspection: 306736695 - Mike'S Roofing, Inc.
Inspection Information - Office: Avenel Area Office
Site Address:
Mike'S Roofing, Inc.
128 Cokesbury Rd.
Lebanon, NJ 08822
Mailing Address:
27 East 33rd St., Paterson, NJ 07514
Union Status: NonUnion
SIC:1761
NAICS: 238160/Roofing Contractors
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 02/12/2004
Emphasis: S:Construction, S:Construction Fatalities
Case Closed: 07/27/2004
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101310886 | ||
Referral | 201318110 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 6 | 1 | 7 | |||
Current Violations | 2 | 1 | 4 | 7 | ||
Initial Penalty | $10,500 | $0 | $3,000 | $0 | $0 | $13,500 |
Current Penalty | $2,000 | $0 | $2,000 | $0 | $0 | $4,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 5A0001 | 02/12/2004 | 03/31/2004 | $1,000 | $3,000 | $0 | 04/16/2004 | R - Review Commission | |
2. | 01001B | Serious | 19260050 B | 02/12/2004 | 03/31/2004 | $0 | $0 | $0 | 04/16/2004 | R - Review Commission | |
3. | 01002 | Other | 19260100 A | 02/12/2004 | 02/18/2004 | $0 | $1,125 | $0 | 04/16/2004 | R - Review Commission | |
4. | 01003 | Other | 19260102 A01 | 02/12/2004 | 02/18/2004 | $0 | $1,125 | $0 | 04/16/2004 | R - Review Commission | |
5. | 01004A | Serious | 19260501 B01 | 02/12/2004 | 02/18/2004 | $1,000 | $3,000 | $0 | 04/16/2004 | R - Review Commission | |
6. | 01004B | Serious | 19260501 B08 II | 02/12/2004 | 02/18/2004 | $0 | $0 | $0 | 04/16/2004 | R - Review Commission | |
7. | 01005 | Other | 19260502 H01 III | 02/12/2004 | 03/03/2004 | $0 | $1,125 | $0 | 04/16/2004 | R - Review Commission | |
8. | 01006A | Other | 19101200 E01 | 02/12/2004 | 03/31/2004 | $0 | $1,125 | $0 | 04/16/2004 | R - Review Commission | |
9. | 01006B | Other | 19101200 G01 | 02/12/2004 | 03/31/2004 | $0 | $0 | $0 | 04/16/2004 | R - Review Commission | |
10. | 01006C | Other | 19101200 H | 02/12/2004 | 03/31/2004 | $0 | $0 | $0 | 04/16/2004 | R - Review Commission | |
11. | 02001 | Repeat | 19260021 B02 | 02/12/2004 | 03/31/2004 | $2,000 | $3,000 | $0 | 04/16/2004 | R - Review Commission |
Investigation Summary
On August 16, 2003, a roofer employed by Mike's Roofing, Inc. had been installing a hot asphalt roof at the Round Valley Middle School in Lebanon, NJ. At approximately 2:30 p.m., the roofer informed his coworker that he did not feel well and climbed down a ladder to the ground below. He sat in an air conditioned car driven by the coworker's girlfriend, for some 15-20 minutes before other workers checked on his condition prior to leaving the site upon completion of work activities. Coworkers noted that the roofer breathing was labored and his skin was dry with white splotches. The foreman directed that the roofer be driven to the nearest hospital for treatment. The foreman's cell phone was not working properly so he could not call for the emergency medical services. En route to the hospital the roofer's condition deteriorated and he was transferred to a Whitehouse, NJ ambulance and MICU from the Hunterdon Medical Center. His body temperature was recorded at 108 degree Farenheit upon admission to the hospital and he was transferred to the ICU where he subsequently died due to heat stroke related body system failure.
Keywords: ROOF, HEAT STROKE, ASPHALT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 306736695 | Fatality | Other | Roofers |