Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1125065.015
Citation: 01001
Citation Type: Serious
Abatement Date: 02/19/2018 2
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 06/29/2016
Nr Instances: 2
Nr Exposed: 8
Related Event Code (REC): R
Gravity: 10
Report ID: 0636900
Contest Date: 07/21/2016
Final Order: 12/15/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 12/15/2017 | $7,000.00 | 02/19/2018 | Serious | |
Penalty | C: Contested | 07/25/2016 | $7,000.00 | 07/21/2016 | Serious | |
Penalty | Z: Issued | 06/29/2016 | $7,000.00 | 07/21/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. The employer's energy control procedures did not include a specific procedure for employee to shut down the horizontal electrical rotary machine when employees cleared jams involving the rotary valve on the Re-feed system.