Violation Detail
Standard Cited: 19260451 B01 General requirements.
Inspection Nr: 1248336.015
Citation: 01001
Citation Type: Serious
Abatement Date: 01/18/2018 2
Initial Penalty: $5,174.00
Current Penalty: $4,555.00
Issuance Date: 01/11/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0215000
Contest Date: 01/26/2018
Final Order: 06/22/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/22/2018 | $4,555.00 | 01/18/2018 | Serious | |
Penalty | C: Contested | 02/07/2018 | $5,174.00 | 01/18/2018 | Serious | |
Penalty | Z: Issued | 01/11/2018 | $5,174.00 | 01/18/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Location: a) Supported scaffold on the southeast side of the first floor of the jobsite: On or about 07/12/17, employees were installing CMU blocks on the first tier platform of a single-tier-high supported scaffold that was not fully planked or decked between front upright and the guardrail supports, and were exposed to falling approximately 16 feet to the lower level.