Violation Detail
Standard Cited: 19101000 A02 Air contaminants.
Inspection Nr: 1415159.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/10/2020
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 03/10/2020
Emphasis:
Substance: 0560
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 01/10/2020 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.1000(a)(2): Employees were exposed to an airborne concentration of Carbon Monoxide listed in Table Z-1 in excess of the 8-hour Time-Weighted Average concentration of 50 parts per million particles of air (50 ppm) for any 8-hour work shift of a 40-hour work week and attenuated accordingly for extended work shifts in extended work weeks: On or about July 13, 2019, at 10788 SW 188th Street, Cutler Bay, FL 33157, an employee was exposed to an 8-hour TWA of 869 ppm of carbon monoxide, derived from biological monitoring, when operating a propane powered sanding machine in a shop with the doors closed.