Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1594464.015
Citation: 01001
Citation Type: Serious
Abatement Date: 07/28/2022 2
Initial Penalty: $14,502.00
Current Penalty: $7,976.10
Issuance Date: 06/01/2022
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A;R
Gravity: 10
Report ID: 0729700
Contest Date:
Final Order: 06/21/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/21/2022 | $7,976.10 | 07/28/2022 | Serious | |
Penalty | Z: Issued | 06/01/2022 | $14,502.00 | 06/28/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: At the north building at 4425 W. May St in Wichita KS, employee(s) were exposed to amputations hazards in that the grate covering the chip conveyor was removed on the Modig Rigimill and the machine was in use and not locked out which resulted in an amputation of an employee's knee.