Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1604473.015
Citation: 01001
Citation Type: Serious
Abatement Date: 01/13/2023 2
Initial Penalty: $14,502.00
Current Penalty: $8,700.00
Issuance Date: 12/07/2022
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0213900
Contest Date:
Final Order: 12/27/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/27/2022 | $8,700.00 | 01/13/2023 | Serious | |
Penalty | Z: Issued | 12/07/2022 | $14,502.00 | 12/15/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a - 433 Stokes Avenue, Ewing NJ: The employer failed to utilize energy control procedures when performing maintenance or when servicing a McNeilus Front Loader's tail gate. Violation noted on or about 06/23/22. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.