Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1640590.015
Citation: 01001
Citation Type: Other
Abatement Date: 08/19/2024 2
Initial Penalty: $14,063.00
Current Penalty: $14,063.00
Issuance Date: 06/12/2023
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0418600
Contest Date: 07/06/2023
Final Order: 05/20/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 05/20/2024 | $14,063.00 | 08/19/2024 | Other | |
Penalty | C: Contested | 07/07/2023 | $14,063.00 | 06/21/2023 | Serious | |
Penalty | Z: Issued | 06/12/2023 | $14,063.00 | 06/21/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Optimized Sharp Chain Line: On or about December 21, 2022, the employer exposed employees to crushed-by hazards in that the employer did not conduct a periodic inspection of the 3155 Primary Profiling Module energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.