Violation Detail
Standard Cited: 19100134 C01 Respiratory Protection.
Inspection Nr: 1501967.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 06/03/2021 2
Initial Penalty: $13,653.00
Current Penalty: $8,750.00
Issuance Date: 04/27/2021
Nr Instances: 4
Nr Exposed: 6
Related Event Code (REC): A;P
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 05/14/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/14/2021 | $8,750.00 | 06/03/2021 | Serious | |
Penalty | Z: Issued | 04/27/2021 | $13,653.00 | 06/03/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i)-(ix) with worksite-specific procedures was not established and implemented for required respirator use: Generations at Lincoln, LLC, 100 Hall located at 811 West 2nd Street, Byron, Illinois: On or about October 29, 2020 to November 17, 2020, the employer did not develop and implement a written respiratory protection program with worksite-specific procedures for respirator use that included all provisions in 29 CFR 1910.134(c)(1)(i)-(ix). The employer required employees to wear respirators througout their shifts while exposed to suspected or confirmed positive COVID-19 residents. The employees were required to wear respirators, Markrite Sekura N-95 , to protect from airborne biohazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.13(d).