Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1682618.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 01/08/2024
Initial Penalty: $15,625.00
Current Penalty: $0.00
Issuance Date: 12/07/2023
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC): A
Gravity: 10
Report ID: 0521100
Contest Date: 12/27/2023
Final Order: 09/18/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/18/2024 | $0.00 | 01/08/2024 | Serious | |
Penalty | C: Contested | 12/27/2023 | $15,625.00 | 01/08/2024 | Serious | |
Penalty | Z: Issued | 12/07/2023 | $15,625.00 | 01/08/2024 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the requirements of section(c)(4)(ii)(A)-(c)(4)(ii)(D) of this standard. On or about July 10, 2023, with regard to an establishment located at 1111 Greenheck Drive, Schofield, WI 54476, the employer did not ensure that the hazardous energy controls procedures for Integrated Blanking System #1, including the Operator Safety Control Zones, provided clear and specific guidance for effective means and methods of hazardous energy control during service and maintenance tasks. Operators utilizing the Operator Safety Control Zone portion of the hazardous energy control plan could still access hazard areas when the methods described in the plan allowed for options that did not control potentially hazardous energy.