Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1722111.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 08/02/2024
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 07/11/2024
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): A
Gravity: 10
Report ID: 0213600
Contest Date: 07/26/2024
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 08/08/2024 | $16,131.00 | 08/02/2024 | Serious | |
Penalty | Z: Issued | 07/11/2024 | $16,131.00 | 08/02/2024 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 01/18/2024, in the production area; where energy control procedures for the non-routine task of removing the die-cut drum from the LANGSTON TITAN Rotary Die Cutter machine (machine number 4561/784) did not include the potential energy of the raised weight (the 4000 pound die-cut drum) in the types and magnitude of energy available on the machine. ABATEMENT DOCUMENTATION REQUIRED