Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 624938.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 12/05/2012 5
Initial Penalty: $2,000.00
Current Penalty: $1,500.00
Issuance Date: 12/04/2012
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0317000
Contest Date:
Final Order: 12/04/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/04/2012 | $1,500.00 | 12/05/2012 | Serious | |
Penalty | Z: Issued | 12/04/2012 | $2,000.00 | 12/05/2012 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a) Jobsite - 1413 South 19th Street- A ladder or other safe means of access was not provided to employees working on the tubular welded scaffold. Employees were using the side frames and cross bracing to access the working levels. Obsreved on or about 09/11/12.