Violation Detail
Standard Cited: 19100147 C04 II C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1339751.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 02/21/2020 2
Initial Penalty: $11,641.00
Current Penalty: $0.00
Issuance Date: 12/04/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0729700
Contest Date: 12/21/2018
Final Order: 01/21/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/21/2020 | $0.00 | 02/21/2020 | Serious | |
Penalty | C: Contested | 12/27/2018 | $11,641.00 | 01/23/2019 | Serious | |
Penalty | Z: Issued | 12/04/2018 | $11,641.00 | 01/23/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. Employee(s) were exposed to amputation hazards. On or about August 9, 2018, an employee engaged in maintenance activities handling ingredient scale #2 located in blending facility was exposed to amputation hazards in that specific procedural steps for placement, removal and transfer of lockout devices and the responsibility related to the pneumatic gate was not developed, documented and utilized.