Violation Detail
Standard Cited: 19100134 H01 Respiratory Protection.
Inspection Nr: 1489156.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 03/22/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/24/2021
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): P
Gravity: 10
Report ID: 0420300
Contest Date:
Final Order: 03/18/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/24/2021 | $0.00 | 03/22/2021 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.134(h)(1): Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer: a) Womack Army Medical Center located at 2817 Reilly Road, Fort Bragg, NC 28310 On or about August 20, 2020 and at times prior to, the Moldex 8112N half-face elastomeric respirator was not cleaned and disinfected according to the manufacturer recommendations or Appendix B-2. The agency required employees to wear respirators throughout their shifts while exposed to suspected or confirmed positive COVID-19 patients.