Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1510861.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 07/23/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/07/2021
Nr Instances: 38
Nr Exposed: 38
Related Event Code (REC): A;P
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 07/01/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/01/2021 | $0.00 | 07/23/2021 | Serious | |
Penalty | Z: Issued | 06/07/2021 | $0.00 | 07/23/2021 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator or annually refitted: a) Ratliff Care Center located at 717 North Sprigg Street in Cape Girardeau, MO: On or about 1/21/2021, the employer did not provide a fit test to all employees required to wear respirators. The employer required employees to wear N95 filtering facepiece respirators to protect against the SARS-CoV-2 virus while providing care to suspected and confirmed positive COVID-19 residents. The violation occurred on or about 1/21/2021 and after.