Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1524248.015
Citation: 01001D
Citation Type: Serious
Abatement Date: 07/27/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/15/2021
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): A;P
Gravity: 10
Report ID: 0215800
Contest Date: 08/06/2021
Final Order: 09/13/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 09/13/2021 | $0.00 | 07/27/2021 | Serious | |
Penalty | C: Contested | 08/11/2021 | $0.00 | 07/27/2021 | Serious | |
Penalty | Z: Issued | 07/15/2021 | $0.00 | 07/27/2021 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) CLR Carthage Center LLC DBA Carthage Center, located at 1045 West Street, Carthage, NY: On or about 1/15/2021 and thereafter, the employer permitted the use of a N95 respirator after an employee failed the fit test and was not retested with other respirator make(s), model(s),or size(s) to assure a good fit. The employer required the employee[s]to wear N95 filtering facepiece respirators to protect against the SARS-CoV-2 virus while providing care to suspected and confirmed positive COVID-19 residents.