Violation Detail
Standard Cited: 19100146 E01 Permit-required confined spaces
Inspection Nr: 965405.015
Citation: 01002
Citation Type: Serious
Abatement Date: 10/24/2014 2
Initial Penalty: $7,000.00
Current Penalty: $5,000.00
Issuance Date: 09/22/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 10/20/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/20/2014 | $5,000.00 | 10/24/2014 | Serious | |
Penalty | Z: Issued | 09/22/2014 | $7,000.00 | 10/24/2014 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.146(e)(1): Before entry is authorized, the employer shall document the completion of measures required by paragraph (d)(3) of this section by preparing an entry permit. NOTE: Appendix D to section 1910.146 presents examples of permits whose elements are considered to comply with the requirements of this section. The employer failed to prepare an entry permit prior to employees inserting an extended wrench into the quench tank chamber of the AFE-6 Casemaster furnance to adjust the quench tank elevator.