Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1048428.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 10/02/2015 2
Initial Penalty: $5,390.00
Current Penalty: $2,209.90
Issuance Date: 08/17/2015
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 09/14/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/14/2015 | $2,209.90 | 10/02/2015 | Serious | |
Penalty | Z: Issued | 08/17/2015 | $5,390.00 | 10/02/2015 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a/ Inside of the Reclaim Department, on or about 03/19/15, the 480 volt electrical disconnect belonging to the Tumbler Rotary Valve, unknown make, model, or serial number, was not turned off prior to an employee reaching in to clear a jam. This employee suffered from multiple amputations of his fingers.