Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1285233.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 05/24/2018
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/19/2018
Nr Instances: 1
Nr Exposed: 8
Related Event Code (REC): R
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 05/14/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/14/2018 | $0.00 | 05/24/2018 | Serious | |
Penalty | Z: Issued | 04/19/2018 | $0.00 | 05/24/2018 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control. The procedures did not clearly and specifically outline the requirements for testing water-cooled hearth rolls to determine if water which is capable of producing 3rd degree steam burns had been removed.