Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1593815.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 11/14/2022 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/23/2022
Nr Instances: 37
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0728500
Contest Date:
Final Order: 10/17/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/17/2022 | $0.00 | 11/14/2022 | Serious | |
Penalty | Z: Issued | 09/23/2022 | $0.00 | 11/10/2022 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Workplace located at 2700 W. 16th St., Sedalia, Missouri- Hallway between Lehr 5 and Lehr 6- Fans 28 & 29 and similar fans were not fully guarded shaft in which employees were required to work above the improperly guarded pulleys and shafts in order to ignite pilot lights.