Violation Detail
Standard Cited: 19100253 B02 II Oxygen-fuel gas welding and cutting.
Inspection Nr: 1298997.015
Citation: 01003
Citation Type: Serious
Abatement Date: 10/18/2018 2
Initial Penalty: $3,880.00
Current Penalty: $2,328.00
Issuance Date: 08/30/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 09/27/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/27/2018 | $2,328.00 | 10/18/2018 | Serious | |
Penalty | Z: Issued | 08/30/2018 | $3,880.00 | 10/18/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Assigned storage spaces were not located where cylinders would not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a. Coastal Landfill maintenance area - Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. The oxygen and acetylene compressed gas cylinders were stored within 20 feet of a 55-gallon drum of used oil and two 5-gallon containers of gasoline. b. Coastal Landfill maintenance area - Oxygen and acetylene compressed gas cylinders were not secured from falling. c. Coastal Landfill maintenance area - Oxygen and acetylene compressed gas cylinders were stored together.