Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1394552.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $7,672.00
Current Penalty: $0.00
Issuance Date: 10/17/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 5
Report ID: 0214500
Contest Date: 11/04/2019
Final Order: 05/07/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/07/2020 | $0.00 | Serious | ||
Penalty | C: Contested | 11/04/2019 | $7,672.00 | Serious | ||
Penalty | Z: Issued | 10/17/2019 | $7,672.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Mixer Area: The employer's energy control procedure for locking out the Teka Mixers for routine cleaning and maintenance was not inspected at least annually, on or about 4/19/2019.