Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
This violation item has been deleted.
Inspection Nr: 1409432.015
Citation: 01003
Citation Type: Serious
Abatement Date: 1
Initial Penalty: $5,683.00
Current Penalty: $0.00
Issuance Date: 12/02/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 1
Report ID: 0418200
Contest Date:
Final Order: 01/14/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/14/2020 | $0.00 | Serious | ||
Penalty | Z: Issued | 12/02/2019 | $5,683.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: (a) West-facing side of I-Guide Platform: On or before June 13, 2019, and at times prior, the employer exposed employees to struck-by hazards, in that the employer did not install guard on C1 I-Guide motor fan (Model # Unknown, S/N Unknown) .