Violation Detail
Standard Cited: 19260553 A04 Base-mounted drum hoists.
Inspection Nr: 1462605.015
Citation: 01003
Citation Type: Serious
Abatement Date: 08/31/2020
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/06/2020
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0419400
Contest Date: 09/22/2020
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 09/23/2020 | $0.00 | 08/31/2020 | Serious | |
Penalty | Z: Issued | 08/06/2020 | $0.00 | 08/31/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.553(a)(4): All base-mounted drum hoists in use did not meet the applicable requirements for design, construction, installation, testing, inspection, maintenance, and operations, as prescribed by the manufacturer. (a) Hoist - On or about February 7, 2020 the employer did not ensure the Hydradyne tower hoist had an operator's manual on site, controls clearly marked and easily accessible, documented daily inspections on-site, and a winch elapse time meter, exposing employees to struck by hazards.