Violation Detail
Standard Cited: 19260502 E02 Fall protection systems criteria and practices.
Inspection Nr: 1508869.015
Citation: 01003
Citation Type: Serious
Abatement Date: 02/16/2021 5
Initial Penalty: $4,096.00
Current Penalty: $4,096.00
Issuance Date: 02/04/2021
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): A
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 03/03/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/04/2021 | $4,096.00 | 02/16/2021 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.502(e)(2):Positioning devices shall be secured to an anchorage capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds (13.3 kN), whichever is greater. a) Jose Oliverio Larios Morales, at a jobsite located at 7125 Sea Breeze West, Building 5, Sunbury, Ohio 43074 : On and/or preceding January 2, 2021, the employer failed to ensure anchorages were capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds. Employees used ropes, which were nailed through the ropes to the roof, for positioning while working on the roof of a three story apartment building. This lack of an adequate anchorage thereby exposed the employees to fall hazards of 30 feet.