Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1575839.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $14,502.00
Current Penalty: $0.00
Issuance Date: 07/29/2022
Nr Instances: 2
Nr Exposed: 6
Related Event Code (REC):
Gravity: 10
Report ID: 0317300
Contest Date:
Final Order: 08/30/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/30/2022 | $0.00 | Serious | ||
Penalty | Z: Issued | 07/29/2022 | $14,502.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) DMSS Unloading (R0222 Bag Dump Station) - On or about January 30, 2022, the employer failed, the employer failed to protect employees from amputations and other hand injuries by not: 1. apprising an authorized employee of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy before process equipment such as, but not limited to, an energized rotary vane-valve is deenergized; and, 2. ensuring that an orderly shutdown of machine process equipment such as, but not limited to, an energized rotary vane-valve, is utilized to avoid any additional or increased hazards to employees as a result of equipment stoppage.