Standard Cited: 19260502 B01 Fall protection systems criteria and practices.
Inspection Nr: 978341.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,200.00
Current Penalty: $2,200.00
Issuance Date: 06/12/2014
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 0112000
Contest Date: 08/26/2014
Final Order: 03/16/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/16/2016 | $2,200.00 | Serious | ||
Penalty | C: Contested | 09/02/2014 | $2,200.00 | Serious | ||
Penalty | Z: Issued | 06/12/2014 | $2,200.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: On or about 04/18/2014 at the Farmington Motor Inn Roofing Project, employees were installing a roofing system and the parapet wall in use as fall protection was not 42 inches in height.