Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1357545.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 02/06/2019
Initial Penalty: $9,282.00
Current Penalty: $0.00
Issuance Date: 01/25/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 02/07/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/07/2019 | $0.00 | 02/06/2019 | Serious | |
Penalty | Z: Issued | 01/25/2019 | $9,282.00 | 02/06/2019 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a. Located at 3610 West Pike, Zanesville, OH: On or about November 01, 2018, the employer did not conduct periodic inspection of the energy control (lock-out, tag-out) procedure for the two types of balers at the facility location. The baler machines at the facility included the horizontal (Maren, Model: 72/60-301, Horizontal Closed Door Baler and vertical (CRAM-A-LOT, Model VB-72) balers. The facility had nine vertical and three horizontal balers.