Violation Detail
Standard Cited: 19261203 A
Inspection Nr: 1515365.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 09/20/2021 2
Initial Penalty: $8,778.00
Current Penalty: $20,000.00
Issuance Date: 08/16/2021
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): A;I
Gravity: 5
Report ID: 0216000
Contest Date: 09/09/2021
Final Order: 07/01/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/01/2022 | $20,000.00 | 09/20/2021 | Serious | |
Penalty | C: Contested | 09/16/2021 | $8,778.00 | 09/20/2021 | Serious | |
Penalty | Z: Issued | 08/16/2021 | $8,778.00 | 09/20/2021 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1926.1203(a): Before beginning work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary. A) 133 East Clarke Place, Bronx NY: The employer did not ensure that a competent person evaluated all confined spaces where the employees may work, including the elevator pit, to determine that it was a permit space due to the stored energy from an elevator car above, on or before February 18th, 2021. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.