Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1553596.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 04/15/2022 2
Initial Penalty: $14,502.00
Current Penalty: $11,000.00
Issuance Date: 03/10/2022
Nr Instances: 4
Nr Exposed: 4
Related Event Code (REC): A
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order: 04/04/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/04/2022 | $11,000.00 | 04/15/2022 | Serious | |
Penalty | Z: Issued | 03/10/2022 | $14,502.00 | 04/07/2022 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): Energy isolating devices were not used to de-energize Trumpf laser material handling area: a. On or about September 17, 2021, a maintenance employee entered the material handling area to adjust slat bolts on index table. b. On or about September 17, 2021, and October 19, 2021, laser operators entered the material handling area to clean the index table slats. c. On or about October 01, 2021, to October 08, 2021, laser operators entered the material handling area to replace index table slats. d. On or about September 17, 2021, laser operators entered the material handling area to perform cleaning activities.