Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1630356.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 05/01/2023 2
Initial Penalty: $5,156.00
Current Penalty: $4,124.80
Issuance Date: 04/05/2023
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0830400
Contest Date:
Final Order: 04/24/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/24/2023 | $4,124.80 | 05/01/2023 | Serious | |
Penalty | Z: Issued | 04/05/2023 | $5,156.00 | 05/01/2023 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): (a)Associated Milk Producers, Inc. at 127 Commercial Avenue in Hoven, SD 57450: On or about and at times prior to October 19, 2022, the employer did not ensure employees were protected from caught-in and nip-point hazards in that the motor of the Curd and Whey Transfer Pump PF-8 not fully enclosed exposing employees to caught-in hazards created by movement of the associated belt and pulley. This condition exposed employees to caught-in and nip point hazards.