Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1689181.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 02/22/2024 2
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 02/07/2024
Nr Instances: 1
Nr Exposed: 12
Related Event Code (REC): A
Gravity: 10
Report ID: 0627100
Contest Date: 03/05/2024
Final Order: 10/07/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/07/2024 | $16,131.00 | 02/22/2024 | Serious | |
Penalty | C: Contested | 03/06/2024 | $16,131.00 | 02/22/2024 | Serious | |
Penalty | Z: Issued | 02/07/2024 | $16,131.00 | 02/22/2024 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about August 8, 2023, at the BMM Molding Machine, employees performed maintenance activities including, but not limited to repairing the "bend gates " on machinery and equipment such as, but not limited as the 10861 BMM Molding Machine without using machine specific energy control procedures.