Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1044433.015
Citation: 01004
Citation Type: Serious
Abatement Date: 10/30/2015 2
Initial Penalty: $3,500.00
Current Penalty: $1,750.00
Issuance Date: 08/13/2015
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 08/28/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | $1,750.00 | 10/30/2015 | Serious | ||
Penalty | I: Informal Settlement | 08/28/2015 | $1,750.00 | 10/30/2015 | Serious | |
Penalty | Z: Issued | 08/13/2015 | $3,500.00 | 08/24/2015 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. a. Tiffin Metal Products Co. located in Tiffin, Ohio: On or about March 12, 2015, the employer did not ensure an employee performing die set up on the Garco 65 ton full revolution mechanical power press located in the Building #2 welding department was applying a lockout device to the electrical disconnect, dissipating pneumatic energy from the clutch mechanism, and inserting die blocks prior to performing set-up operations. b. Tiffin Metal Products Co. Located in Tiffin, Ohio: On or about March 19, 2015, the employer did not ensure an employee performing set up on the Piranha ironworker located in the Building #1 "Pit" was applying a lockout device to the electrical disconnect prior to performing set-up operations on the equipment.