Violation Detail
Standard Cited: 19100119 J04 III Process safety management of highly hazardous chemicals.
Inspection Nr: 1374931.015
Citation: 01004
Citation Type: Serious
Abatement Date: 08/16/2019
Initial Penalty: $13,260.00
Current Penalty: $13,260.00
Issuance Date: 07/25/2019
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 10
Report ID: 0419400
Contest Date: 08/20/2019
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 11/25/2019 | $13,260.00 | 08/16/2019 | Serious | |
Penalty | Z: Issued | 07/25/2019 | $13,260.00 | 08/16/2019 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience. a) On or about January 29, 2019, at Wayne Farm's LLC in Laurel, MS, the employer did not performed testing, and inspections on Condenser EC-6 , in accordance with manufacturer recommendations, to discover and prevent corrosion or other mechanical integrity discrepancies that could cause equipment failure.