Violation Detail
Standard Cited: 19100140 D02 II
Inspection Nr: 1531496.015
Citation: 01004
Citation Type: Serious
Abatement Date: 09/13/2021 2
Initial Penalty: $2,340.00
Current Penalty: $1,638.00
Issuance Date: 08/20/2021
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0523900
Contest Date:
Final Order: 09/13/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/13/2021 | $1,638.00 | 09/13/2021 | Serious | |
Penalty | Z: Issued | 08/20/2021 | $2,340.00 | 09/13/2021 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.140(d)(2)(ii): The employer did not ensure that personal fall arrest systems are rigged in such a manner that the employee cannot free fall more than 6 feet (1.8 m) or contact a lower level. A free fall may be more than 6 feet (1.8 m) provided the employer can demonstrate the manufacturer designed the system to allow a free fall of more than 6 feet and tested the system to ensure a maximum arresting force of 1,800 pounds (8 kN) is not exceeded: (a) Warehouse area; The employer did not ensure that a six-foot internal shock lanyard, used by employees while picking and storing products from a multi-tiered racking system, would prevent employees from contacting a lower level in the event of a fall.