Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1102198.015
Citation: 01004A
Citation Type: Serious
Abatement Date: 02/04/2016 2
Initial Penalty: $5,100.00
Current Penalty: $3,570.00
Issuance Date: 01/08/2016
Nr Instances: 1
Nr Exposed: 15
Related Event Code (REC):
Gravity: 5
Report ID: 0418300
Contest Date:
Final Order: 02/09/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/09/2016 | $3,570.00 | 02/04/2016 | Serious | |
Penalty | Z: Issued | 01/08/2016 | $5,100.00 | 02/04/2016 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) On or about 10/28/15 - at the Banding Area of the Run-out table, the horizontal shafting for the chain conveyor adjacent to the employee walkway platform was not enclosed.