Violation Detail
Standard Cited: 19261053 B05 I Ladders.
Inspection Nr: 1219568.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/12/2017
Nr Instances: 5
Nr Exposed: 1
Related Event Code (REC):
Gravity: 1
Report ID: 0134000
Contest Date: 07/11/2017
Final Order: 01/15/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/15/2018 | $0.00 | Serious | ||
Penalty | C: Contested | 07/17/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 06/12/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder. (a) Location - 427 Lincoln Street, Waltham, MA. On or about March 23, 2017, an employee was not protected from falling while using non self-supporting ladders that were not set up at the proper angle.